Pentax DSI-200 Series Frequency Inverter User Manual
This document serves as the user manual for the Pentax DSI-200 Series high-performance vector frequency inverter. It covers essential safety precautions, installation guidelines, wiring procedures, and operational instructions to ensure the proper and safe use of the device. The guide emphasizes the importance of reading safety warnings before installation, commissioning, and maintenance to prevent injury or equipment damage.
Read onlinePentax DSI-200 specifications
| Highest frequency | 0~500Hz |
|---|---|
| Speed range | 1:100 |
| Speed control accuracy | ±0.5% |
| Overload capacity (G type) | 150% rated current 60sec |
| Carrier frequency | 0.8kHz -12kHz |
| Altitude level | Less than 1000m |
| Environment temperature | -10℃~+40℃ |
Source: Pentax DSI-200 Series Frequency Inverter User Manual
All Pentax DSI-200 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What safety precautions should be taken before installation?
Do not install the inverter in a control system with water or where parts are missing or damaged. Ensure the packing list matches the physical items.
What are the main protection functions of the inverter?
The inverter includes protection against power-on motor short circuit, output phase-loss, over-current, over-voltage, under-voltage, and overheat.
What is the maximum frequency range for the Pentax DSI-200 Series inverter?
The inverter supports a maximum frequency range of 0 to 500Hz for both vector control and V/F control.
What is the required time interval between power ON/OFF cycles?
If continuous ON/OFF power is needed, the time interval must be more than 1 minute.