Maximator S35 Manuals

ManualLib has 3 documents for the Maximator S35: 2 datasheets, 1 parts list. Every file can be read online or downloaded as a PDF for free.

Datasheet 2Parts List 1

Key facts

Model
S35
Documents
3
Languages
DE · EN
Last added
2012-07-11

Start here

Maximator S35D Pneumatic Hydraulic Pump Datasheet

Maximator S35D Pneumatic Hydraulic Pump Datasheet

Datasheet 4 pages · 381 KB · DE

This document is a technical datasheet for the Maximator S35D, a double-acting pneumatic hydraulic pump. It provides key operational parameters such as a drive air pressure range of 1-10 bar and a calculated operating pressure of 380 bar at 10 bar air input. The unit features a translation ratio of 1:38 and is constructed with an aluminum pump body and hardened steel pistons. This manual is written in German.

Read online

Maximator S35 specifications

Drive air pressure1-10 bar
Calculated operating pressure380 bar
Translation ratio1:38
Hub volume (double stroke)25.2 cm3
Inlet connection3/4 BSP
Outlet connection3/4 BSP
Air connection1/2 BSP
Max. operating temperature60°C
Weight14.5 kg
Pump Body MaterialGGG50
Piston Material1.4112 (hardened)
Height260 mm

Source: Maximator S35D Pneumatic Hydraulic Pump Datasheet

All Maximator S35 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the maximum operating pressure of the S35D?

The maximum operating pressure is 380 bar when driven by 10 bar of air pressure.

From: Maximator S35D Pneumatic Hydraulic Pump Datasheet

Is the S35D available with NPT connections?

Yes, it is available with side inlet/outlet options such as NPT (S35D-NPT).

From: Maximator S35D Pneumatic Hydraulic Pump Datasheet

How many check valves does this repair kit cover?

The repair kit contains spare parts for only one check valve.

From: Maximator S 35-05-215 Repair Kit Parts List

What does the repair kit contain?

The repair kit contains only the spare parts for one check valve.

From: Maximator S 35-05-215 Repair Kit Parts List

What is the maximum operating temperature?

The maximum operating temperature is 60°C.

From: Maximator S35 Pneumatic Pump Datasheet

What is the maximum operating temperature for the Maximator S35 pump?

The maximum operating temperature is 60°C.

From: Maximator S35 Pneumatic Pump Datasheet