Lascar EM20-FPSI 1010 Datasheet

Lascar EM20-FPSI 1010 Datasheet

Datasheet 3 pages · 90 KB · EN

The EM20-FPSI 1010 is a two‑colour voltage level indicator designed for panel mounting. It compares an input voltage to a programmable window and shows red, green, or red‑green‑red LEDs to indicate whether the voltage is below, within, or above the window. The module operates from a 7 V to 24 V DC supply, offers two user‑programmable thresholds, a control output, low‑power flashing mode, and is housed in a metal bezel with IP67/NEMA 4X protection.

Installation is done via screw terminals with a 20.5 mm cut‑out. The indicator can be configured by storing threshold voltages using a jumper link, and the alarm output goes low when the measured voltage is outside the set range. The datasheet provides full electrical specifications, circuit diagrams, and wiring examples for driving relays, opto‑isolators, and triacs.

Read online

Lascar FPSI 1010 specifications

Supply voltage7.0 – 24.0 V
Supply current (display not flashing)15 mA
Supply current (display flashing)2.5 mA
Input voltage range0 – 30 Vdc
Internal resolution30 mV
Accuracy±2 %
Operating temperature range-30 °C to 50 °C
IP protection ratingIP67 / NEMA 4X

Source: Lascar EM20-FPSI 1010 Datasheet

All Lascar FPSI 1010 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What voltage range does the EM20-FPSI 1010 measure?

It measures input voltages from 0 V to 30 V dc.

From: Lascar EM20-FPSI 1010 Datasheet

How many user‑programmable thresholds are available?

The module provides two user‑programmable thresholds.

From: Lascar EM20-FPSI 1010 Datasheet

What supply voltage does the FPSI 1010 require?

It operates from a 4.75 to 5.5 V d.c. supply.

From: Lascar FPSI 1010 Colour Voltage Level Indicator Datasheet

What input voltage range can the FPSI 1010 measure?

The range is 0 to 2.5 V d.c. when Vref is not connected, and 0 to 5.0 V d.c. when Vref is connected to +5.0V.

From: Lascar FPSI 1010 Colour Voltage Level Indicator Datasheet