Klein Tools VDV500-820E Toner-Pro / Probe-Pro Kit Instruction Manual
The Klein Tools VDV500-820E kit instruction manual covers the VDV500-063 Toner-Pro tone generator and VDV500-123 Probe-Pro tone tracer. It describes wire identification and tracing on non-energised wires, RJ11/RJ12/RJ45 jack testing, continuity and polarity checks, and the Probe-Pro worklight and headphone jack.
The manual lists general specifications for both instruments, including batteries, dimensions, weight, temperatures, tones, battery life and auto power-off. It also includes warnings and operating instructions for continuity testing, selecting tone frequency, tracing paired and non-paired wires, verifying toned pairs, and testing polarity and voltage presence.
Klein Tools VDV500-820 specifications
| Operating Altitude | 6562 ft. (2000 m) maximum |
|---|---|
| Relative Humidity | 10% – 90% non-condensing |
| Operating Temp | 14° to 122°F (-10° to 50°C) |
| Storage Temp | -4° to 140°F (-20° to 60°C) |
| Tone Frequencies | Constant: 800Hz, 1000Hz, 1500Hz; Alternating: 800Hz/1000Hz, 1000Hz/1500Hz |
| Continuity Indication | Less than 10kΩ |
| Tone Power | 8dBm |
| Battery Type | 4 x 1.5V AAA Alkaline |
Source: Klein Tools VDV500-820 Pro Tone and Probe Kit User Manual
All Klein Tools VDV500-820 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What does the 'CONT' indicator show?
The 'CONT' indicator illuminates green to indicate a successful continuity test (less than 10kΩ resistance), or red to indicate a short circuit.
From: Klein Tools VDV500-820 Pro Tone and Probe Kit User Manual
How do I select a tone frequency on the Toner-Pro?
Use the Tone Mode Up and Tone Mode Down selector buttons to change the frequency. The Tone Frequency Indicators will display the selected frequency.
From: Klein Tools VDV500-820 Pro Tone and Probe Kit User Manual
What is the maximum operating altitude for this device?
The maximum operating altitude is 6562 ft. (2000 m).
From: Klein Tools VDV500-820 Toner-Pro / Probe-Pro Kit Instruction Manual
What type of batteries are required?
The device requires 4 x 1.5V AAA Alkaline batteries.
From: Klein Tools VDV500-820 Toner-Pro / Probe-Pro Kit Instruction Manual
What is the Toner-Pro designed for?
It is a professional-series tone generator for wire identification, wire tracing and wire pair identification on non-energised wires.
From: Klein Tools VDV500-820E Toner-Pro / Probe-Pro Kit Instruction Manual
Which jacks can the RJ11 Test Plug work with?
It works with RJ11, RJ12 or RJ45 jacks.
From: Klein Tools VDV500-820E Toner-Pro / Probe-Pro Kit Instruction Manual