Kemppi FastMig M 320 Manuals

ManualLib has 7 documents for the Kemppi FastMig M 320: 7 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 7

Key facts

Brand
Kemppi
Model
FastMig M 320
Documents
7
Languages
ZH · PT · EN · ES · SV
Last added
2023-11-03

Start here

Kemppi FastMig M 320, 420, 520 Operating Manual

Kemppi FastMig M 320, 420, 520 Operating Manual

User Manual 15 pages · 853 KB · EN

This manual covers the installation, operation, and maintenance of the Kemppi FastMig M 320, 420, and 520 power sources. These multi-purpose units are designed for demanding professional use in DC MMA and MIG welding applications. The document details setup procedures, including positioning and electrical connections, as well as the use of accessories like remote controls and wire feeders.

Read online

Kemppi FastMig M 320 specifications

Mains voltage400 V, 3-phase
Power cable length5 m
Control fuse6.3 A time-delay
Protection ratingIP23S
Maximum installation inclination15 degrees
Cooling air clearanceAt least 20 cm front and rear
Recommended welding cable cross-section, FastMig M 32050-70 mm²
Recommended welding cable cross-section, FastMig M 42070-90 mm²
Recommended welding cable cross-section, FastMig M 52070-90 mm²
Short-circuit power requirement, FastMig M 420Ssc at least 5.6 MVA
Short-circuit power requirement, FastMig M 520Ssc at least 5.8 MVA
IEC 61000-3-12 compliance, FastMig M 320Not compliant
Continuous voltage withstand3 x 440 V
Automatic control stop voltage limitsBelow about 300 V or above about 480 V

Source: Kemppi FastMig M 320, 420, 520 Welding Power Source User Manual

All Kemppi FastMig M 320 documents by type

Questions answered in these manuals

What mains voltage can the FastMig M 320, 420 and 520 be connected to?

The power source can be connected to 400 V three-phase mains power.

From: Kemppi FastMig M 320, 420, 520 Welding Power Source User Manual

What fuse protects the auxiliary equipment?

A 6.3 A time-delay fuse on the rear wall protects the auxiliary equipment.

From: Kemppi FastMig M 320, 420, 520 Welding Power Source User Manual

What is the maximum cable cross-section for FastMig M 520?

70 – 90 mm².

From: Kemppi FastMig M 320, 420, 520 User Manual

What does the H12 LED indicate?

Thermal protection has been activated due to overheating.

From: Kemppi FastMig M 320, 420, 520 User Manual

What is the minimum short-circuit power required for the FastMig M 520?

The equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc is greater than or equal to 5.8 MVA.

From: Kemppi FastMig M 320, 420, 520 Operating Manual

Can the FastMig M 320 be connected to a public low voltage system?

No, this equipment does not comply with IEC 61000-3-12 and requires consultation with the distribution network operator before connection.

From: Kemppi FastMig M 320, 420, 520 Operating Manual