KB Electronics KBMG-212D Regenerative Drive Installation and Operation Manual
This manual provides installation and operating instructions for the KBMG-212D regenerative drive, designed for shunt wound and permanent magnet DC motors. It covers wiring, jumper settings, mounting, fusing, and trimpot adjustments. Safety warnings and operational modes including 4-quadrant control are detailed. The drive supports both speed and torque control modes and includes performance specifications and electrical ratings.
The manual includes tables for electrical ratings, control operation, and performance specifications, as well as figures for jumper settings and wiring connections. It emphasizes safety precautions and proper installation to avoid fire or electrocution risks.
KB Electronics KBMG-212D specifications
| Input AC line voltage | 115 V, 230 V (50/60 Hz) |
|---|---|
| DC armature voltage | 90 V, 180 V |
| Control mode | Speed, Torque |
| DC output current (selectable) | 1.7 A, 2.5 A, 5.0 A, 7.5 A, 10 A |
| Analog input voltage range | 0‑10 V or 0‑15 V |
| Enable functions | Inertia slide to stop (CTS), Regeneration to stop (RTS) |
| Power rating (115 V) | 0.1‑1 HP (90 V DC) |
| Power rating (230 V) | 0.2‑2 HP (180 V DC) |
| Maximum load capacity | 150 % for 2 minutes |
All KB Electronics KBMG-212D documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the maximum horsepower for the KBMG-212D without auxiliary heatsink?
The maximum horsepower is 0.75 HP (0.5 kW) at 115VAC and 1.5 HP (1.0 kW) at 230VAC.
From: KB Electronics KBMG-212D Regenerative Drive Installation and Operation Manual
What type of motors is the KBMG-212D drive designed to operate?
The drive is designed for shunt wound and permanent magnet (PM) DC motors.
From: KB Electronics KBMG-212D Regenerative Drive Installation and Operation Manual
What input voltages does the KBMG-212D support?
It accepts either 115 V or 230 V AC at 50/60 Hz.
Which motor types can be controlled by the KBMG-212D?
It can control permanent‑magnet and separately‑excited DC motors.