This is a manual for installing and using the KBMG-212D variable speed drive
This manual provides installation and operating instructions for the KBMG-212D regenerative drive, designed for shunt wound and permanent magnet DC motors. It covers wiring, jumper settings, mounting, fusing, and trimpot adjustments. Safety warnings and operational modes including 4-quadrant control are detailed. The drive supports both speed and torque control modes and includes performance specifications and electrical ratings.
The manual includes tables for electrical ratings, control operation, and performance specifications, as well as figures for jumper settings and wiring connections. It emphasizes safety precautions and proper installation to avoid fire or electrocution risks.
| AC Line Voltage | 115VAC or 230VAC |
|---|---|
| Motor Voltage | 0 – ±90VDC or 0 – ±180VDC |
The maximum horsepower is 0.75 HP (0.5 kW) at 115VAC and 1.5 HP (1.0 kW) at 230VAC.
The drive is designed for shunt wound and permanent magnet (PM) DC motors.
Jumper J2 is factory set for 7.5 amp motors.