Hanna Instruments HI 9813-6 Manuals

ManualLib has 4 documents for the Hanna Instruments HI 9813-6: 1 quick start guide, 2 user manuals. Every file can be read online or downloaded as a PDF for free.

Quick Start Guide 1User Manual 2

Key facts

Model
HI 9813-6
Industry
Appliances
Documents
4
Languages
EN
Last added
2012-07-10

Start here

Hanna Instruments HI 9813-6 pH/EC/TDS/°C Meter Quick Reference Guide

Hanna Instruments HI 9813-6 pH/EC/TDS/°C Meter Quick Reference Guide

Quick Start Guide 2 pages · 67 KB · EN

This document serves as a quick reference guide for the Hanna Instruments HI 9813-6 pH/EC/TDS/°C meter. It provides step-by-step instructions for taking measurements, including connecting the HI 1285-6 probe, selecting the desired range, and waiting for thermal equilibrium. It also details the procedure for replacing the 9V alkaline battery when the meter turns off due to low power.

Read online

Hanna Instruments HI 9813-6 specifications

Temperature Coefficient2%/°C
Warranty Period (Meter)Two years
Warranty Period (Probes)Six months

Source: Hanna Instruments HI 9813-5/6 Portable pH/EC/TDS Meters Instruction Manual

All Hanna Instruments HI 9813-6 documents by type

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What battery is required for the HI 9813-6 meter?

The meter requires a 9V alkaline battery.

From: Hanna Instruments HI 9813-6 pH/EC/TDS/°C Meter Quick Reference Guide

What should be done if the display shows only a '1'?

If the display shows only a '1', the meter is out of range.

From: Hanna Instruments HI 9813-6 pH/EC/TDS/°C Meter Quick Reference Guide

How often should the instrument be recalibrated?

It is recommended to recalibrate frequently, specifically whenever the electrode is replaced, at least once a month, after testing aggressive chemicals, or if extreme accuracy is required.

From: Hanna Instruments HI 9813-5/6 Portable pH/EC/TDS Meters Instruction Manual

What indicates that cleaning is needed during calibration?

If turning the knob cannot reach the needed value, or if the Cal-Check feature displays 'Clean Probe and Calibrate', cleaning is required.

From: Hanna Instruments HI 9813-5/6 Portable pH/EC/TDS Meters Instruction Manual

What is the temperature coefficient of the meter?

The temperature coefficient is fixed at 2%/°C.

From: HI 9813-0 HI 9813-5 HI 9813-6 Portable pH/EC/TDS/°C Meters Instruction Manual

How often should the instrument be recalibrated for pH?

It is recommended to recalibrate whenever the electrode is replaced, at least once a month, after testing aggressive chemicals, or if extreme accuracy is required.

From: HI 9813-0 HI 9813-5 HI 9813-6 Portable pH/EC/TDS/°C Meters Instruction Manual