Key facts
- Brand
- Grundfos
- Model
- SEG 0.9-4.0 kW
- Category
- Other products
- Documents
- 2
- Languages
- EN · ZH
- Last added
- 2026-10-15
Start here

Grundfos SEG 0.9-4.0 kW Pump Installation and Operating Instructions
This Chinese-language manual provides installation and operating instructions for Grundfos SEG 0.9-4.0 kW pumps. It covers safety notices, operating conditions, electrical data, variable-frequency drive operation, transport, mechanical installation, lifting, automatic coupling installation, electrical connection and startup.
It states operating limits including intermittent S3 operation, continuous S1 operation when fully submerged, a minimum installation depth of 10 m below liquid level, maximum operating pressure of 6 bar, maximum 30 starts per hour, pH 4-10, liquid temperature 0-40 °C, IP68 protection and insulation class F. This manual is written in Chinese.
Grundfos SEG 0.9-4.0 kW specifications
| Operating mode | Intermittent (S3); continuous (S1) when fully submerged in the pumped liquid |
|---|---|
| Minimum installation depth | 10 m below liquid level |
| Maximum operating pressure | 6 bar |
| pH range | 4 to 10 |
| Liquid temperature | 0-40 °C |
| Short-term liquid temperature | Maximum 60 °C for up to 15 minutes (non-explosion-proof pumps only) |
| Sound pressure level | Below the limit specified by EC 2006/42/EC Machinery Directive |
| Power supply voltage | 1 x 230 V -10%/+6%, 50 Hz; 3 x 230 V -10%/+6%, 50 Hz; 3 x 400 V -10%/+6%, 50 Hz |
| Protection rating | IP68 (IEC 60529) |
| Insulation class | F (155 °C) |
| External grounding conductor cross-section (explosive environments) | At least 4 mm² |
| Explosion-proof pump liquid temperature limit | Not above 40 °C |
Source: Grundfos SEG 0.9-4.0 kW Pump Installation and Operating Instructions
All Grundfos SEG 0.9-4.0 kW documents by type
Disassembly, diagnostics and part numbers, for repair.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
Who must service pumps with explosion-proof motors?
Service work on Ex pumps must be carried out by Grundfos or a workshop authorised by Grundfos.
From: Grundfos SEG 0.9-4.0 kW Wastewater Pump Service Instructions
What supervision is required for work in pits?
All work in pits must be supervised by a person outside the pump pit.
From: Grundfos SEG 0.9-4.0 kW Wastewater Pump Service Instructions
What is the minimum installation depth for the pump?
The minimum depth is 10 m below the liquid level.
From: Grundfos SEG 0.9-4.0 kW Pump Installation and Operating Instructions
Can the pump run continuously?
It can run continuously (S1) when fully submerged in the pumped liquid; otherwise it is designed for intermittent operation (S3).
From: Grundfos SEG 0.9-4.0 kW Pump Installation and Operating Instructions