Grundfos SEG 0.9-4.0 kW Pump Installation and Operating Instructions

Grundfos SEG pumps are designed for intermittent operation (S3), but this pump type can also run continuously (S1) when the pump is completely submerged in the pumped liquid.


Grundfos SEG 0.9-4.0 kW Pump Installation and Operating Instructions - cover page
Brand
Grundfos
Category
Other products
Document type
User Manual
Language
Chinese
Pages
34
File format
PDF
File size
4.6 MB
Published
22 November, 2023
Updated
22 November, 2023
MD5 checksum
421FF2AF7A9A4324D96F2D43AB249C7D

About this manual

This Chinese-language manual provides installation and operating instructions for Grundfos SEG 0.9-4.0 kW pumps. It covers safety notices, operating conditions, electrical data, variable-frequency drive operation, transport, mechanical installation, lifting, automatic coupling installation, electrical connection and startup.

It states operating limits including intermittent S3 operation, continuous S1 operation when fully submerged, a minimum installation depth of 10 m below liquid level, maximum operating pressure of 6 bar, maximum 30 starts per hour, pH 4-10, liquid temperature 0-40 °C, IP68 protection and insulation class F. This manual is written in Chinese.

What's inside

  • Safety instructions and other important information
  • Operating conditions
  • Electrical data
  • Variable-frequency drive operation
  • Transporting the product
  • Installing the product
  • Mechanical installation
  • Lifting the product
  • Installation to automatic coupling
  • Electrical connection

Specifications

Operating modeIntermittent (S3); continuous (S1) when fully submerged in the pumped liquid
Minimum installation depth10 m below liquid level
Maximum operating pressure6 bar
pH range4 to 10
Liquid temperature0-40 °C
Short-term liquid temperatureMaximum 60 °C for up to 15 minutes (non-explosion-proof pumps only)
Sound pressure levelBelow the limit specified by EC 2006/42/EC Machinery Directive
Power supply voltage1 x 230 V -10%/+6%, 50 Hz; 3 x 230 V -10%/+6%, 50 Hz; 3 x 400 V -10%/+6%, 50 Hz
Protection ratingIP68 (IEC 60529)
Insulation classF (155 °C)
External grounding conductor cross-section (explosive environments)At least 4 mm²
Explosion-proof pump liquid temperature limitNot above 40 °C

Frequently asked questions

What is the minimum installation depth for the pump?

The minimum depth is 10 m below the liquid level.

Can the pump run continuously?

It can run continuously (S1) when fully submerged in the pumped liquid; otherwise it is designed for intermittent operation (S3).

What liquid temperatures are allowed?

Normally 0-40 °C; short-term operation up to 15 minutes allows up to 60 °C for non-explosion-proof pumps.

What power supply voltages are listed?

1 x 230 V, 3 x 230 V and 3 x 400 V, all at 50 Hz with -10%/+6% tolerance.