Key facts
- Brand
- Grundfos
- Model
- UPM3
- Industry
- Industrial
- Documents
- 3
- Languages
- EN
- Last added
- 2026-11-16
Start here

Grundfos UPM3 Pump Settings Quick Guide
This quick guide lists recommended setting indications for the Grundfos UPM3 pump in underfloor heating, radiator heating one-pipe and two-pipe systems, and domestic water circulation. It also mentions constant curves for fixed rotation speed and recommends heating-system-specific energy optimised pump functions.
The guide includes troubleshooting for pump faults, including no power, a blocked axle or impeller, low supply voltage, and severe malfunction, with corresponding checks and solutions. Alarm status categories shown are fault, blocked, low voltage, and electrical error.
Grundfos UPM3 specifications
| Ambient Temperature | up to 70° Celsius |
|---|---|
| Bearing Shaft Material | Ceramic |
| De-blocking System | Double safety de-blocking system |
All Grundfos UPM3 documents by type
The shortest path to a working setup, usually only a few pages.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What should I check if the Grundfos UPM3 pump does not function and has no power?
Check that the power plug is plugged in and the switch is turned on.
What should I do if the LED is lit and an axle or impeller is stuck?
Press on the screw in front of the pump and turn it using a screwdriver to release the axle or impeller.
How do I manually deblock the pump if it’s seized?
Use a Phillips screwdriver No.2, insert it into the hole in the front plate, push toward the pump, and turn it counter-clockwise.
What happens if the pump is blocked?
The pump will try to start every 1.33 seconds with LED 1 red and LED 5 yellow, and can be manually freed using the deblocking device.
Which applications is the UPM3 designed for?
The UPM3 range is designed for boiler systems, heat pumps, solar thermal systems, heating kits, DHW systems, and micro CHP systems.
What is the maximum ambient temperature the UPM3 can handle?
The UPM3 is designed to perform perfectly in ambient temperatures of up to 70° Celsius.