GoodWe SEC1000 Manuals

ManualLib has 3 documents for the GoodWe SEC1000 (Power Management): 3 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 3

Key facts

Brand
Goodwe
Model
SEC1000
Documents
3
Languages
EN · ES
Last added
2026-11-07

Start here

GoodWe SEC1000 V1.1 Smart Energy Controller User Manual

GoodWe SEC1000 V1.1 Smart Energy Controller User Manual

User Manual 15 pages · 2.4 MB · EN

The GoodWe SEC1000 V1.1 Smart Energy Controller user manual provides safety, mounting, installation, technical parameter, and commissioning information for the device. It describes ports, wiring, communication interfaces, indicators, and grid connection procedures.

The manual includes instructions for selecting an installation location, mounting the unit, connecting AC voltage input and output ports, CTs, LAN, and RS485 communication, and commissioning the equipment with indicator status descriptions.

Read online

GoodWe SEC1000 specifications

Input phase voltage rangeAC60V-AC280V
Input line voltage rangeAC100V-AC480V
AC Frequency50/60Hz
AC cable wire diameterNo more than 25 mm
485 communication cable conductor area≥AWG14

Source: GoodWe SEC1000 V1.1 Smart Energy Controller User Manual

All GoodWe SEC1000 documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What grid structure does the SEC1000 support?

It supports the three-phase four-wire grid structure only.

From: GoodWe SEC1000 V1.1 Smart Energy Controller User Manual

What is the input phase voltage range of the SEC1000?

The input phase voltage range is AC60V-AC280V.

From: GoodWe SEC1000 V1.1 Smart Energy Controller User Manual

What is the default IP address for SEC1000S in static mode?

The default IP address is 192.168.1.200.

From: GoodWe SEC1000S Smart Energy Controller User Manual

Does SEC1000S support three-phase four-wire grid structures?

Yes, it supports the three-phase four-wire grid structure only.

From: GoodWe SEC1000S Smart Energy Controller User Manual

What is the input voltage range for the SEC1000?

The phase input voltage range is 60 V-280 V AC and the line input voltage range is 100 V-480 V AC.

From: GoodWe SEC1000 Smart Energy Controller User Manual

What are the minimum clearance requirements for mounting the SEC1000?

The SEC1000 requires at least 500 mm clearance at the top and bottom, 200 mm on each side, and 500 mm in front.

From: GoodWe SEC1000 Smart Energy Controller User Manual