GoodWe SDT G2 Series Photovoltaic Grid-connected Inverter User Manual
This user manual provides comprehensive instructions for the GoodWe SDT G2 Series photovoltaic grid-connected inverters, covering models with rated output powers from 5kW to 25kW. It details the product's application scenarios, circuit diagrams, and physical appearance for different power ranges (5-15kW and 17-25kW).
The document guides users through the entire lifecycle of the device, including pre-installation checks, installation requirements, electrical connections for DC input and AC output, and communication setup. It also explains how to configure parameters via the display or mobile APP, perform system commissioning, and conduct regular maintenance or fault troubleshooting. This manual is written in Chinese.
GoodWe SDT G2 Series specifications
| Max. Efficiency | Up to 98.4% |
|---|---|
| Number of MPP Trackers | 2 |
| Operating Temperature Range | -30 ~ +60 °C |
| Ingress Protection Rating | IP65 |
| Max. Input Voltage | 1000V or 1100V |
| Max. Output Current | Up to 31.9 A |
Source: GoodWe SDT G2 Series 5-20kW Three Phase Inverter Datasheet
All GoodWe SDT G2 Series documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the maximum efficiency of the SDT G2 Series inverter?
The maximum efficiency of the SDT G2 Series inverter is 98.4%.
From: GoodWe SDT G2 Series 5-20kW Three Phase Inverter Datasheet
What is the maximum operating altitude for the SDT G2 Series?
The maximum operating altitude for the SDT G2 Series is 3000 meters.
From: GoodWe SDT G2 Series 5-20kW Three Phase Inverter Datasheet
Who is authorized to install and maintain this inverter?
Installation, operation, maintenance, and replacement must only be performed by qualified professionals or trained personnel.
From: GoodWe SDT G2 Series Photovoltaic Grid-connected Inverter User Manual
What tools are required for operating the inverter?
Insulated tools must be used, and personal protective equipment should be worn to ensure safety.
From: GoodWe SDT G2 Series Photovoltaic Grid-connected Inverter User Manual