Key facts
- Brand
- Glenair
- Model
- Series 79
- Category
- electronic components
- Industry
- Electronics
- Documents
- 4
- Languages
- EN
- Last added
- 2026-11-17
Start here

Glenair Series 79 Panel Mount Connectors Datasheet
This Glenair datasheet covers Series 79 panel mount connectors, including the 790-072S rear panel mounted plug with solder cup socket contacts. It provides ordering information, shell finish options, hardware options, and contact arrangement layouts.
The document lists electrical specifications, materials and finishes, and dimensional tables for shell sizes A through M. It also describes contact sizes, wire acceptance, and available accessories such as EMI springs and shielding adapters.
Glenair Series 79 specifications
| Current Rating #23 | 5 AMPS |
|---|---|
| Dielectric Withstanding Voltage #23 | 750 VAC RMS |
| Dielectric Withstanding Voltage #12 and #16 | 1800 VAC RMS |
| Insulation Resistance | 5000 megohms minimum |
| Operating Temperature | -65° C. to +150° C. |
| Shock | 300 g. |
| Vibration | 20 g. |
All Glenair Series 79 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the part number for the rear panel mounted plug with solder cup socket contacts?
790-072S.
What wire size do size #23 signal pins accept?
Up to #22 AWG wire.
What wire sizes do the 790-026P contacts accept?
Size #23 signal pins accept up to #22 AWG wire, size #16 contacts accept #16-18 AWG wire, and size #12 contacts accept #12-14 AWG wire.
From: Glenair 790-026P Series 79 Micro-Crimp Panel Mount Receptacle Catalog and How to Order
Can the connectors accept coaxial contacts?
Yes, size 12 and 16 cavities also accept coaxial contacts purchased separately.
From: Glenair 790-026P Series 79 Micro-Crimp Panel Mount Receptacle Catalog and How to Order
What is the basic part number of the connector?
The basic part number is 790-066.
From: Glenair L-9L790-066 Series 79 Micro-Crimp Hermetic Receptacle Datasheet
What hermeticity limit is specified?
Hermeticity is specified as less than 1 x 10-7 scc He/sec at 1 ATM.
From: Glenair L-9L790-066 Series 79 Micro-Crimp Hermetic Receptacle Datasheet