Garan EWS 102 Control Unit User Manual
The EWS 102 is a compact control unit for elevator load weighing, designed for easy installation on DIN rail or flat surfaces. It provides alarm outputs and auto-zero calibration to prevent errors from friction or compensation chains. The unit supports analog outputs for pre-torque control and can be configured via a keypad with LED display. Calibration and setup are guided by step-by-step procedures and flowcharts.
The manual includes wiring instructions for sensors and relays, control signal setup, and detailed parameter adjustments such as maximum capacity, alarm thresholds, filter settings, and system reset options.
GARAN EWS-102 specifications
| Power Supply | 12-24VDC |
|---|---|
| Default Capacity | 1000 kg |
| Alarm Relay 1 Trigger Value | 1100 kg |
| Alarm Relay 3 Trigger Value | -300 kg |
| Hysteresis Value | 30 kg |
All GARAN EWS-102 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How do I calibrate the EWS-102?
Zero calibration is initiated by pressing the and buttons together followed by . Ensure the cabin is empty and press to start. Load calibration follows by placing a known weight and entering its value using the and buttons, then pressing .
What is the 4-20mA output used for?
The 4-20mA output provides an analog signal proportional to the elevator load and allows the controller to pre-torque the motor. It is available in the current loop model only.
How does the system reset function work?
When enabled, the system will automatically recalibrate to zero if the elevator remains inactive for 2 minutes. It must be turned off during calibration.
What types of analog outputs are supported?
The EWS 102 supports current outputs (4-20mA, 0-20mA, 0-24mA) and voltage outputs (0-5V, 0-10V, +/-5V, +/-10V).