Flagro P-200 Manuals

ManualLib has 2 documents for the Flagro P-200 (Heater): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
Flagro
Model
P-200
Category
Heater
Documents
2
Languages
EN
Last added
2023-10-26

Start here

FLAGRO FVNP-200RC Indirect Fired Space Heater Operating Instructions Manual

FLAGRO FVNP-200RC Indirect Fired Space Heater Operating Instructions Manual

User Manual 19 pages · 1005 KB · EN

The FLAGRO FVNP-200RC is a dual-fuel indirect fired space heater rated at 200,000 btuh and intended primarily for temporary heating of buildings under construction, alteration, repair, or emergencies. It is certified for use in Canada and the U.S.A. under ANSI Z83.7/CSA 2.14 2000 and is cETLus listed.

The operating instructions cover installation by a qualified gas technician, clearance to combustibles, electrical supply and grounding, cylinder connection, piping and pressure requirements, fuel selection, power indicator light meanings, flue pipe venting, ducting, maintenance, and start-up. The heater uses propane or natural gas, and the fuel selector valve must be set to the proper fuel position.

Read online

Flagro P-200 specifications

ModelFVP-200 propane; FVN-200 natural gas
Input200,000 btuh
FuelPropane or natural gas
Manifold pressure3.5 in. W.C. propane; 3.5 in. W.C. natural gas
Maximum inlet pressure13.0 in. W.C. propane; 10.0 in. W.C. natural gas
IgnitionDirect spark ignition; thermostat control
Air circulation1500 cfm
Fuel consumption9.25 lbs/hr propane; 190 cfh natural gas
Clearance to combustiblesTop 3 ft; front 10 ft; sides 1 ft; rear 2 ft; flue pipe 3 ft
Electrical supply115 V
Current requirement15 A
Weight280 lbs

Source: Flagro FVN/P-200 Indirect Fired Space Heaters Operating Instructions Manual

All Flagro P-200 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What fuel can the FVN/P-200 use?

It will operate on propane or natural gas, but not both; the rating plate determines which fuel to use.

From: Flagro FVN/P-200 Indirect Fired Space Heaters Operating Instructions Manual

How much fresh air ventilation is required?

The instructions require 1 sq. in. of fresh air for every 1000 BTUH of heat.

From: Flagro FVN/P-200 Indirect Fired Space Heaters Operating Instructions Manual

What fuel does the FVNP-200RC use?

It operates on propane and natural gas; the manual describes it as a dual fuel unit.

From: FLAGRO FVNP-200RC Indirect Fired Space Heater Operating Instructions Manual

What electrical supply does the heater require?

It requires 115V, 15 AMP service, with a 6 AMP draw.

From: FLAGRO FVNP-200RC Indirect Fired Space Heater Operating Instructions Manual