Key facts
Start here

FLAGRO FVNP-200RC Indirect Fired Space Heater Operating Instructions Manual
The FLAGRO FVNP-200RC is a dual-fuel indirect fired space heater rated at 200,000 btuh and intended primarily for temporary heating of buildings under construction, alteration, repair, or emergencies. It is certified for use in Canada and the U.S.A. under ANSI Z83.7/CSA 2.14 2000 and is cETLus listed.
The operating instructions cover installation by a qualified gas technician, clearance to combustibles, electrical supply and grounding, cylinder connection, piping and pressure requirements, fuel selection, power indicator light meanings, flue pipe venting, ducting, maintenance, and start-up. The heater uses propane or natural gas, and the fuel selector valve must be set to the proper fuel position.
Flagro P-200 specifications
| Model | FVP-200 propane; FVN-200 natural gas |
|---|---|
| Input | 200,000 btuh |
| Fuel | Propane or natural gas |
| Manifold pressure | 3.5 in. W.C. propane; 3.5 in. W.C. natural gas |
| Maximum inlet pressure | 13.0 in. W.C. propane; 10.0 in. W.C. natural gas |
| Ignition | Direct spark ignition; thermostat control |
| Air circulation | 1500 cfm |
| Fuel consumption | 9.25 lbs/hr propane; 190 cfh natural gas |
| Clearance to combustibles | Top 3 ft; front 10 ft; sides 1 ft; rear 2 ft; flue pipe 3 ft |
| Electrical supply | 115 V |
| Current requirement | 15 A |
| Weight | 280 lbs |
Source: Flagro FVN/P-200 Indirect Fired Space Heaters Operating Instructions Manual
All Flagro P-200 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What fuel can the FVN/P-200 use?
It will operate on propane or natural gas, but not both; the rating plate determines which fuel to use.
From: Flagro FVN/P-200 Indirect Fired Space Heaters Operating Instructions Manual
How much fresh air ventilation is required?
The instructions require 1 sq. in. of fresh air for every 1000 BTUH of heat.
From: Flagro FVN/P-200 Indirect Fired Space Heaters Operating Instructions Manual
What fuel does the FVNP-200RC use?
It operates on propane and natural gas; the manual describes it as a dual fuel unit.
From: FLAGRO FVNP-200RC Indirect Fired Space Heater Operating Instructions Manual
What electrical supply does the heater require?
It requires 115V, 15 AMP service, with a 6 AMP draw.
From: FLAGRO FVNP-200RC Indirect Fired Space Heater Operating Instructions Manual