Key facts
- Brand
- FANUC
- Model
- 320s-MODEL A
- Category
- Industrial Robot
- Documents
- 3
- Languages
- EN · JA
- Last added
- 2023-10-17
Start here
FANUC Series 30*/300*/300*s-MODEL A/31*/310*/310*s-MODEL A5/31*/310*/310*s-MODEL A/32*/320*/320*s-MODEL A User Manual
This manual covers safety information for CNC equipment, including warnings, cautions, and notes that must be read before use. It explains how to safely start the machine, perform tool checks, and handle programming functions.
Detailed sections describe general warnings, programming-specific cautions, tool‑interference checks, absolute/incremental mode considerations, axis speed control, and the required stroke check after power‑on. This manual is written in Japanese.
All FANUC 320s-MODEL A documents by type
Disassembly, diagnostics and part numbers, for repair.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- FANUC Series 30*/300*/300*s-MODEL A/31*/310*/310*s-MODEL A5/31*/310*/310*s-MODEL A/32*/320*/320*s-MODEL A User Manual 437 p
- OPERATOR’S MANUAL B-64004EN/02 FANUC Series 30*/300*/300*s-MODEL A FANUC Series 31*/310*/310*s-MODEL A5 FANUC Series 31*/310*/310*s-MODEL A FANUC Series 32*/320*/320*s-MODEL A Dual Check Safety 174 p
Questions answered in these manuals
Who is authorized to perform CNC maintenance?
CNC maintenance must be undertaken only by a qualified technician.
How long must power be off before replacing a unit?
Allow at least twenty minutes after turning off the power for residual voltages to dissipate.
What must be done before touching the MDI panel keys after power‑on?
Wait until the position display or alarm screen appears on the CNC screen before touching any MDI panel keys.
How can I avoid tool‑interference problems during automatic operation?
Ensure the tool number programmed for automatic operation matches the actual tool being used.
What is the Dual Check Safety function?
It uses two independent CPUs to monitor motor speed and position, shutting off power to the motor if an error is detected.
Can the Dual Check Safety function monitor the stop state of motors?
No, it cannot monitor the stop state of the motors.