FAFNIR LS 300 Level Detector Safety Manual

Service Manual 3 pages · 144 KB · ES

This safety manual covers the proper use, installation, and maintenance of FAFNIR LS 300 level detectors and LS 500 H SIL measurement converters for SIL 2 safety applications. It includes safety standards, wiring diagrams, diagnostic procedures, and error codes for troubleshooting. The device is designed to prevent overfilling or dry-running in industrial environments.

The manual specifies safe operating conditions, including vibration resistance up to 2g and 55Hz, and provides instructions for firmware version reading via MODBUS-RTU protocol. It also details error handling, including SIL error codes and reset procedures. This manual is written in Spanish.

Read online

FAFNIR LS 500 H SIL ... specifications

Safety Integrity LevelSIL 2
Hardware Fault ToleranceHFT = 0
Mean Time to Recovery8 h
Repetition Test Interval1 año
Response Time (Overfill Protection)2 segundos
Response Time (Dry-Run Protection)20 segundos

Source: FAFNIR LS 300 Level Detector Safety Manual

All FAFNIR LS 500 H SIL ... documents by type

Service Manual 3

Disassembly, diagnostics and part numbers, for repair.

Questions answered in these manuals

How do I read the firmware version via MODBUS-RTU?

Use function code 03 (Read Holding Registers) with addresses 0x0040 and 0x0041 to read the version number.

From: FAFNIR LS 300 Level Detector Safety Manual

What is the SIL error code for memory failure?

Memory failure is indicated by intermittent code 1.

From: FAFNIR LS 300 Level Detector Safety Manual

What safety standard does this device comply with?

The device complies with EN 61508:2010 for functional safety of electrical/electronic/electronic programmable systems, with SIL 2 rating.

From: EN 61508 Safety Manual

How is the device diagnosed for SIL errors?

SIL errors are indicated by a blinking LED "Error" (from firmware 1.2.0.255 and hardware 1.1.0.255), with specific codes for memory, checksum, relay, resistance scanner, transistor scanner, and isolation faults.

From: EN 61508 Safety Manual

What is the minimum resistance value required for the level sensor to detect short circuits?

The resistance value must be less than 30 Ω (or < 2.5 Ω with firmware version 1.0.1.255).

From: FAFNIR LS 300 and LS 500 H SIL Safety Manual

How often should the functionality of the system be checked?

The functionality should be checked at appropriate intervals, but at least once a year.

From: FAFNIR LS 300 and LS 500 H SIL Safety Manual