EM TEST NX5 Telecom Series Datasheet

EM TEST NX5 Telecom Series Datasheet

Datasheet 9 pages · 3 MB · ZH

The EM TEST Compact NX5 Telecom Series is a multifunctional test generator for conducted transients including EFT/Burst, Surge, Telecom-Surge and Power Fail up to 5.5 kV. It features a 7-inch color touch screen, built-in single-phase CDN up to 400V/32A, and supports three-phase testing via external CDN. The device complies with international standards including ECE-R10, EN 55024, and IEC 61000-4-5. It can be operated manually or remotely via Ethernet or optical interface, and includes safety features like interlock and warning lamp. Accessories for magnetic field, capacitive coupling, and verification are available. This manual is written in Chinese.

Read online

EM TEST NX5 specifications

Test Voltage (EFT/Burst)200 V - 5,500 V ± 10 %; 100 V - 2,750 V ± 10 % into 50 ohm
Surge Voltage160 V - 5,000 V ± 10 %
Surge CurrentMax. 2,500 A ± 10 %
Built-in CDNSingle-phase up to 400 V/32 A
Display7-inch color touch screen

Source: EM TEST NX5 Telecom Series Datasheet

All EM TEST NX5 documents by type

Datasheet 3

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the maximum test voltage for EFT/Burst?

The maximum test voltage for EFT/Burst is 5,500 V ± 10% into 50 ohm.

From: EM TEST NX5 Telecom Series Datasheet

Can the NX5 be used for three-phase testing?

Yes, the NX5 can be extended for three-phase testing using an automatically controlled external CDN up to 200 A per phase.

From: EM TEST NX5 Telecom Series Datasheet

What tests does the EM TEST Compact NX5 perform?

It performs conducted transient tests for EFT/BURST, SURGE, TELECOM-SURGE and POWER FAIL up to 5.5 kV.

From: EM TEST Compact NX5 Telecom Series Multifunctional Test Generator Data Sheet

How can the NX5 be operated or controlled remotely?

It can be operated manually from the front touch screen or remotely via its built-in Ethernet or optical interface.

From: EM TEST Compact NX5 Telecom Series Multifunctional Test Generator Data Sheet

Which EMC standards does the Compact NX5 comply with?

It complies with IEC 61000‑4‑4, IEC 61000‑4‑5, IEC 61000‑4‑8, IEC 61000‑4‑9, IEC 61000‑4‑11, IEC 61000‑4‑29, EN 61000‑6‑1, EN 61000‑6‑2, and several other related standards.

From: EM TEST Compact NX5 Product Datasheet

What is the maximum current rating of the three‑phase coupling network?

The external three‑phase coupling network can handle up to 200 A per phase.

From: EM TEST Compact NX5 Product Datasheet