Key facts

Model
CC200
Documents
2
Languages
EN
Last added
2026-11-08

Start here

Copeland CC200 Main Controller Quick Start Guide

Copeland CC200 Main Controller Quick Start Guide

Quick Start Guide 4 pages · 1.3 MB · EN

The Copeland CC200 Main Controller Quick Start Guide provides wiring and installation instructions for the CC200 controller and hardware. It covers mounting on DIN rail, power supply wiring, input and output wiring, and specifications for the controller and power supply.

The document also explains stepper valve wiring and supported Sporlan valve settings, expansion module addressing and installation, and the Cold Chain Connect mobile application for setting parameters, graphing inputs and outputs, setting service overrides, and viewing alarms.

Read online

Copeland CC200 specifications

Power Requirement24VDC
Ambient Operating Temperature14°F to 122°F (-10°C to 50°C)
Storage Temperature-40 to 185°F (-40 to 85°C)
Relative Humidity20-85% RH; non-condensing
MountingDIN Rail
Enclosure Dimensions7 3/16” x 4 5/16” x 3” (W x H x D)
Primary Power120VAC
Secondary Power24VDC
CC200 Power Requirement24VDC 60W
Required Power SupplyCC200 Power Supply 24VDC 60W, Copeland P/N 318-3183
Wire Spec16 AWG or larger diameter wire
RS485 PortsUp to 57.6K Baud; isolated; 150 ohm dipswitch termination
ETH1/ETH2BACnet TCP/IP repeater (Ethernet 10/100)
Bipolar Stepper OutputUp to 500mA/phase; 12 Volt 2-Phase bipolar permanent magnet stepper valves
Unipolar Stepper OutputUp to 300mA/phase; 12 Volt 5-wire unipolar permanent magnet stepper valves

Source: Copeland CC200 Main Controller Quick Start Guide

All Copeland CC200 documents by type

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What power supply is required for the CC200 Main Controller?

The CC200 requires 24VDC 60W. The listed required power supply is the Copeland CC200 Power Supply 24VDC 60W, P/N 318-3183.

From: Copeland CC200 Main Controller Quick Start Guide

How is the CC200 Main Controller mounted?

It is mounted on a DIN rail.

From: Copeland CC200 Main Controller Quick Start Guide

How many cases can the CC200 coordinate in a lineup?

The CC200 supports seamless coordination of refrigeration case lineups with support for up to 8 cases in a lineup.

From: Copeland CC200 Case Controller and 026-1740 R16 Case Display User Guide

Can the CC200 communicate with a supervisory controller?

Yes, it communicates via BACnet or Modbus and is integrated into the Copeland E2E and E3 supervisory controllers, while running completely stand-alone.

From: Copeland CC200 Case Controller and 026-1740 R16 Case Display User Guide