Balluff BTL7-P511-M Manuals

ManualLib has 2 documents for the Balluff BTL7-P511-M (Industrial Robot): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
Balluff
Model
BTL7-P511-M
Documents
2
Languages
DE · EN
Last added
2023-11-18

Start here

Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ Magnetostrictive Position Measuring System Profile 1 User Guide

Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ Magnetostrictive Position Measuring System Profile 1 User Guide

User Manual 164 pages · 11.3 MB · EN

The Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ is a magnetostrictive position measuring system in profile style 1 with a digital P interface. It measures position along a waveguide using a position magnet and outputs digital time information between start and stop pulses.

The guide covers installation and electrical connection, commissioning, P-interface protocol parameters, technical data, accessories, type code, and appendix information. Up to 16 position magnets can be used, with a minimum spacing of 65 mm between them.

Read online

Balluff BTL7-P511-M specifications

Protection ClassII 3 G Ex ec IIC T4 Gc
Protection ClassII 2 D Ex tb IIIC T135 °C Db
EMC Emission StandardEN 55011
EMC Immunity StandardEN 61000-4-2
Explosion Protection CertificationIECEx EPS 13.0004 X

Source: Balluff BTL7-P511-M Micropulse Displacement Transducer User Manual

All Balluff BTL7-P511-M documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the scope of this manual?

This manual describes the construction, function, and adjustment possibilities of the BTL7 micropulse displacement transducer.

From: Balluff BTL7-P511-M Micropulse Displacement Transducer User Manual

Who is the intended audience for this manual?

The manual is addressed to qualified personnel with the necessary knowledge for selection, installation, and operation.

From: Balluff BTL7-P511-M Micropulse Displacement Transducer User Manual

How many position magnets can be used with the BTL7-P511?

Up to 16 position magnets can be used.

From: Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ Magnetostrictive Position Measuring System Profile 1 User Guide

What is the minimum distance between position magnets?

The minimum distance between position magnets must be 65 mm.

From: Balluff BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _ Magnetostrictive Position Measuring System Profile 1 User Guide