BALLUFF BNI IOL-800-000-Z037 Signaling and Display Unit Product Leaflet
The document describes the BALLUFF BNI IOL-800-000-Z037 Signaling and Display Unit, a device featuring a configurable 7-segment display, buzzer function, and IO-Link communication. It includes a list of scope of delivery items such as a lock washer, rubber foot, and mounting screws. This manual is written in Chinese.
Read onlineBALLUFF BNI IOL-800-000-Z037 specifications
| Operating voltage | 18...30.2 VDC |
|---|---|
| Rated operating voltage | DC 24 V |
| Sound frequency | 2800 ± 500 Hz |
| Ambient temperature | -5...50 °C |
| IP rating | IP30 |
| Storage temperature | -25...50 °C |
| Volume | 95 dB/m |
| Cycle time min. | 5 ms |
| Error signal | 110 mA at 24V |
| IO-Link version | 1.1 |
| Application weight | 390.00 g |
| Dimension | 60 x 60 x 138.5 mm |
Source: BALLUFF BNI IOL-800-000-Z037 Signaling and Display Unit Product Leaflet
All BALLUFF BNI IOL-800-000-Z037 documents by type
Questions answered in these manuals
What is the minimum cycle time for the interface?
The minimum cycle time is 5 ms.
From: BALLUFF BNI IOL-800-000-Z037 Signaling and Display Unit Product Leaflet
What is the error signal specification?
The error signal is 110 mA at 24V.
From: BALLUFF BNI IOL-800-000-Z037 Signaling and Display Unit Product Leaflet
What is the operating voltage of the BNI IOL-800-000-Z037?
The effective operating voltage is DC 24 V.
What is the maximum operating temperature?
The maximum ambient temperature is 55°C.