User ManualAllegro A3230 Manual
Allegro A3230 specifications
| Supply Voltage (VCC) Operating Range | 3.6 – 24 V |
|---|---|
| Output Current Limit | 30 – 60 mA |
| Operating Temperature (E range) | -40°C to 83°C |
| Operating Temperature (L range) | 40°C to 150°C |
All Allegro A3230 documents by type
Datasheet 1
Ratings, dimensions and ordering codes, for selection and design work.
User Manual 1
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What external bypass capacitor is recommended for the A3230?
A 0.14 µF capacitor placed close to the Hall sensor between supply and ground is typical.
What is the operating temperature range for the A3230 in the L temperature grade?
The device operates from 40 °C up to 150 °C in the L temperature range.