Aeroflex ATC-601-2 Manuals

ManualLib has 2 documents for the Aeroflex ATC-601-2: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Model
ATC-601-2
Industry
Automotive
Documents
2
Languages
EN
Last added
2023-10-12

Start here

Aeroflex ATC-601-2 Ramp Test Set Operation Manual

Aeroflex ATC-601-2 Ramp Test Set Operation Manual

User Manual 164 pages · 1.7 MB · EN

The Aeroflex ATC-601-2 is a transponder ramp test set designed to generate specific interrogation signals (Modes A, C, S) for testing aircraft transponders. The device operates with an output frequency of 1030 MHz and supports various pulse characteristics required for Mode S interrogations.

Read online

Aeroflex ATC-601-2 specifications

Output Frequency1030 MHz ( ±10 kHz)
Signal Level-57 to -7 dBm typically
Test Range6 feet (1.83 meters) to 300 feet (91.44 meters)
Test Signal Rate235 Hz PRF ( ±5 Hz)

Source: Aeroflex ATC-601-2 Ramp Test Set Operation Manual

All Aeroflex ATC-601-2 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What modes does the ATC-601-2 support?

The unit supports Modes A, C, S, and Intermode.

From: Aeroflex ATC-601-2 Ramp Test Set Operation Manual

How long can the external interface cable be?

All external cables must be 3 meters or less in length for EMC compliance.

From: Aeroflex ATC-601-2 Ramp Test Set Operation Manual

What safety precaution must be taken regarding the chassis assembly?

Do not operate this Test Set with the Chassis Assembly removed from the Case Assembly.

From: Aeroflex ATC-601-2 Ramp Test Set Operation Manual

What is the maximum length allowed for external cables used with the COMM Connector?

All external cables must be 3 meters or less in length to maintain EMC compliance.

From: Aeroflex ATC-601-2 Ramp Test Set Operation Manual