Yuasa NP12-12 Industrial VRLA Battery Data Sheet

Yuasa NP12-12 industrial VRLA battery data sheet with specifications, dimensions, charge voltages, and safety notes.


Yuasa NP12-12 Industrial VRLA Battery Data Sheet - cover page
Brand
Yuasa
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
1
File format
PDF
File size
189 KB
Published
23 November, 2026
Updated
23 November, 2026
MD5 checksum
0C9BC46FFCE2E156BECE8929218EF833

About this manual

Yuasa NP12-12 is an industrial VRLA battery. The data sheet lists electrical, physical, charging, and operating specifications, plus safety, installation, venting, and recycling information.

Certification, design-life, short-circuit current, internal resistance, and impedance details are also included.

What's inside

  • 3rd Party Certifications
  • Short-Circuit Current & Internal Resistance
  • Safety
  • Installation
  • Design Life & Approvals
  • Vent valves
  • Gas release
  • Recycling
  • Specifications

Specifications

Nominal voltage12 V
20-hour rate capacity to 10.5 V at 20°C12 Ah
10-hour rate capacity to 10.8 V at 20°C11.1 Ah
Length151 mm (±1)
Width98 mm (±1)
Height over terminals97.5 mm (±2)
Mass4.05 kg
Terminal typeFASTON - Quickfit / release (JST where stated), 6.35
Storage temperature range-20°C to +60°C (fully charged)
Charge temperature range-15°C to +50°C
Discharge temperature range-20°C to +60°C
Storage capacity loss per month at 20°C3% (approx.)
Case materialStandard ABS (UL94:HB); FR version available (UL94:V0)
Float charge voltage at 20°C (block)13.65 V (±1%)
Float charge voltage at 20°C (cell)2.275 V (±1%)
Cyclic (or boost) charge voltage at 20°C (block)14.5 V (±3%)
Cyclic (or boost) charge voltage at 20°C (cell)2.42 V (±3%)
Float charge current limitNo limit
Cyclic (or boost) charge current limit3 A
Maximum discharge current for 1 second360 A
Maximum discharge current for 1 minute75 A
Internal resistance44.39 mΩ
Impedance at 1 kHz16 mΩ
EUROBAT classificationStandard Commercial
VdS numberG189170
Third-party certificationsISO9001 - Quality Management Systems; Underwriters Laboratories Inc.

Frequently asked questions

What is the nominal voltage of the Yuasa NP12-12 battery?

The nominal voltage is 12 V.

Can the battery be installed in any orientation?

It can be installed and operated in any orientation except permanently inverted.

Can the battery be suspended by its handles?

No, batteries must not be suspended by their handles where fitted.

How should the battery be recycled at end of life?

It must be recycled at the end of life in accordance with local and national laws and regulations.

Download PDF (189 KB)