This file is a user manual for the yuasa ycx series battery. It mainly introduces the safety of the battery, the service life, maintenance methods and other content
This manual provides safety warnings and step-by-step instructions for charging Yuasa YCX series batteries. It covers connecting the charger to batteries, selecting charging modes and rates, and using power supply mode for overdischarged batteries. It also includes troubleshooting tips for common issues.
The charger supports various battery types including lead-acid and lithium-ion, with specific settings for each. Safety precautions are emphasized, including proper ventilation, avoiding sparks, and correct polarity connections.
| Supported Battery Types | 12V conventional lead acid (WET, MF, SMF, CaCa, EFB, AGM, GEL) and compatible lithium (lithium-ion, LiFePO4) |
|---|---|
| Charge Rate Options | 1A, 2A, 4A, 6A, 8A, 12A |
| Power Supply Mode | For recovery of overdischarged batteries; not for other applications |
It is designed to charge 12V conventional lead acid batteries (WET, MF, SMF, CaCa, EFB, AGM, GEL) and compatible lithium (lithium-ion, LiFePO4) batteries only.
Consult the Ah rating on the battery label and use the AMP button on the charger to select the suggested charge rate.
It is designed for recovery of overdischarged batteries which would be too low for the smart charger function to recognise.