Yitiancheng YTC5980 Manuals

ManualLib has 2 documents for the Yitiancheng YTC5980 (Other Electronics): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Model
YTC5980
Industry
Industrial
Documents
2
Languages
ZH
Last added
2026-10-19

Start here

YTC5980 Battery Discharge Tester User Manual

YTC5980 Battery Discharge Tester User Manual

User Manual 29 pages · 3 MB · ZH

The YTC5980 is a professional testing instrument designed for performance detection of 12V to 600V battery series. It features online monitoring, discharge testing, and capacity quick measurement capabilities. The device utilizes a touch screen interface and supports both internal storage and external SD card data storage. This manual is written in Chinese.

Read online

Yitiancheng YTC5980 specifications

Discharge Current Range (48V)0~150A / 0~200A / 0~300A
Discharge Current Range (220V)0~30A / 0~50A / 0~100A
Discharge Current Range (380V)0~20A / 0~50A / 0~100A
Voltage Measurement Accuracy0.5%
Current Measurement Accuracy1%
Sampling Interval5s~1min
Screen Resolution128×64LCD

Source: YTC5980 Intelligent Battery Discharge Monitor User Manual

All Yitiancheng YTC5980 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the sampling interval for data collection?

The system allows a sampling interval ranging from 5 seconds to 1 minute.

From: YTC5980 Intelligent Battery Discharge Monitor User Manual

Can the device estimate battery capacity quickly?

Yes, it can perform a short-term discharge of 10 minutes to estimate the battery bank's capacity.

From: YTC5980 Intelligent Battery Discharge Monitor User Manual

What is the warranty period for defects?

Products are exchangeable within three months of shipment and repaired free of charge within three years.

From: YTC5980 Battery Discharge Tester User Manual

What is the YTC5980 Battery Discharge Tester designed to test?

It is a dedicated instrument for testing lead-acid battery banks where individual cell voltage ranges from 1.2V to 12V.

From: YTC5980 Battery Discharge Tester User Manual