User manual for the Yav Smart V 2AD data acquisition card covering features, connections, and troubleshooting.
About this manual
The Smart V 2AD is a multi‑function data acquisition card with two analog and two digital input channels, RS485 communication, and optional temperature, humidity, PWM, encoder and compass functions. It operates on a 16‑24 V DC supply and supports Windows XP through Windows 10 with Yav’s software platforms.
The manual provides hardware specifications, wiring diagrams, software setup instructions, performance tests, safety guidelines, and detailed troubleshooting steps to help users install, configure, and maintain the device safely and effectively. This manual is written in Chinese.
What's inside
- Quick Start
- Hardware Features
- Analog Input
- Digital Input
- Communication Protocol
- Performance Test
- Troubleshooting
- Specifications
Specifications
| Analog input channels | 2 |
|---|
| Resolution | 16 bit (65535) |
|---|
| Input voltage range | DC0~10 V (default) |
|---|
| Input impedance | 1 MΩ (10 V range) |
|---|
| Sampling rate | 1 Hz default, up to 100 Hz |
|---|
| Measurement accuracy | 0.01 % FS |
|---|
| Operating temperature range | -30 °C to 60 °C |
Frequently asked questions
How many analog input channels does the Smart V 2AD have?
It provides two single‑ended analog input channels.
What is the default input voltage range for the analog channels?
The default range is DC 0 V to 10 V.
What should I check if the card cannot connect to the host PC?
Verify that the power indicator is on, the COM port and baud rate are set correctly (default address 1, baud 9600), and that NI‑VISA is installed for LabVIEW.