Yav Smart V 2AD Data Acquisition Card User Manual

User manual for the Yav Smart V 2AD data acquisition card covering features, connections, and troubleshooting.


Yav Smart V 2AD Data Acquisition Card User Manual - cover page
Brand
Yav
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
32
File format
PDF
File size
3 MB
Published
28 September, 2026
Updated
28 September, 2026
MD5 checksum
1E5E49F1D75307D092ABF534A1CD0326

About this manual

The Smart V 2AD is a multi‑function data acquisition card with two analog and two digital input channels, RS485 communication, and optional temperature, humidity, PWM, encoder and compass functions. It operates on a 16‑24 V DC supply and supports Windows XP through Windows 10 with Yav’s software platforms.

The manual provides hardware specifications, wiring diagrams, software setup instructions, performance tests, safety guidelines, and detailed troubleshooting steps to help users install, configure, and maintain the device safely and effectively. This manual is written in Chinese.

What's inside

  • Quick Start
  • Hardware Features
  • Analog Input
  • Digital Input
  • Communication Protocol
  • Performance Test
  • Troubleshooting
  • Specifications

Specifications

Analog input channels2
Resolution16 bit (65535)
Input voltage rangeDC0~10 V (default)
Input impedance1 MΩ (10 V range)
Sampling rate1 Hz default, up to 100 Hz
Measurement accuracy0.01 % FS
Operating temperature range-30 °C to 60 °C

Frequently asked questions

How many analog input channels does the Smart V 2AD have?

It provides two single‑ended analog input channels.

What is the default input voltage range for the analog channels?

The default range is DC 0 V to 10 V.

What should I check if the card cannot connect to the host PC?

Verify that the power indicator is on, the COM port and baud rate are set correctly (default address 1, baud 9600), and that NI‑VISA is installed for LabVIEW.