Installation and service instructions for Viessmann Solar-Divicon solar control units and solar pump assemblies, versions PS10, PS20, P10 and P20.
Viessmann Solar-Divicon and solar pump assembly installation and service instructions for contractors cover versions PS10, PS20, P10 and P20. The document includes safety instructions, component descriptions, installation steps, electrical connection notes and parts lists.
It describes permitted materials and fittings, locking ring fitting installation, clearances, mounting positions and service information. The Solar-Divicon and solar pump assembly are unsuitable for direct contact with swimming pool water.
| Versions | PS10, PS20, P10, P20 |
|---|---|
| Circulation pump | HE circulation pump, Para 15/7.5 |
| Ball valve size | DN 25 |
| Circulation pump connecting cable | 230 V~ |
| PWM control | PWM control |
Only a competent person (heating engineer/installation contractor).
Isolate the power supply and safeguard against unauthorised reconnection.
Only bronze, brass or stainless steel fittings, copper or stainless steel pipes, or Viessmann stainless steel solar circuit pipes.
Flush the system with heat transfer medium.