The document describes the features and characteristics of the Viessmann DHW heating DHW cylinders and cylinder loading systems.
This technical guide from Viessmann covers DHW heating with Viessmann DHW cylinders, cylinder loading systems and freshwater modules. It presents sizing principles, product information for Vitocell cylinders and Vitotrans units, cylinder selection according to NL factor or continuous output, and sizing to DIN 4708-2 and DIN 1988-300.
It also describes cylinder loading systems using Vitocell 100-L with Vitotrans 222, connections on the DHW and heating sides, DHW circulation pipes and cylinder banks. The appendix includes questionnaires and checklists for sizing DHW cylinders and heat exchangers.
| Vitocell 100-H, type CHA capacity | 130, 160 and 200 l |
|---|---|
| Vitocell 300-H, type EHA capacity | 160, 200, 350 and 500 l |
| Vitocell 100-V capacity | 160, 200 and 300 l |
| Vitocell 100-V, type CVWA capacity | 300, 390 and 500 l |
| Vitocell 300-V, type EVIA-A capacity | 160, 200 and 300 l |
| Vitocell 300-V, type EVIA-A+ capacity | 160 and 200 l |
| Vitocell 300-V, type EVIA-A energy efficiency class | A |
| Vitocell 300-V, type EVIA-A+ energy efficiency class | A+ |
| Vitocell 300-H material | Stainless steel |
| Vitocell 300-H cylinder bank capacities | 700 l, 1000 l, 1500 l |
Systems for residential buildings are often configured in accordance with DIN 4708 Part 2.
Viessmann provides free EDIS software for reliable sizing of DHW systems.
Correct operating temperature, design of the DHW circulation pipe, and connection of the DHW circulation pipe to the DHW cylinder.
Yes. Vitocell 300-H cylinders with 350 and 500 l capacity can be combined with on-site manifolds to form cylinder banks.