Installation and service instructions for contractors for the Viessmann Vitodens 111-W Type B1LD gas condensing storage combi boiler.
This document provides installation and service instructions for contractors for the Viessmann Vitodens 111-W Type B1LD gas condensing storage combi boiler, covering safety, preparation, installation, commissioning, inspection, maintenance, troubleshooting, control unit functions, wiring, specification, disposal and certificates.
The appliance is intended for sealed unvented heating systems complying with EN 12828 and is preset for natural gas. It includes a cylinder and integral plate heat exchanger for DHW heating, and weather-compensated operation is possible by connecting an outside temperature sensor.
| Output range | 4.7 to 35.0 kW |
|---|---|
| Gas Council Number | 47-819-43, 47-819-44 |
| IP rating | IP X4 |
| Power cable | 3 x 1.5 mm2, approx. 1.5 m |
They are exclusively intended for qualified contractors; gas work must be carried out by a registered gas fitter and electrical work by a qualified electrician.
It is intended solely for installation and operation in sealed unvented heating systems complying with EN 12828, heating water of potable water quality.
Yes, by connecting an outside temperature sensor as an accessory.
Do not smoke or create sparks, close the gas shut-off valve, open windows and doors, evacuate people, and notify the gas or electricity supply utility from outside.