Vickers KDG5V Series Proportional Directional Control Valve User Manual

This manual covers the design, function, model coding, operating data, and installation details for Vickers KDG5V-5/7/8/10 proportional directional control…


Vickers KDG5V Series Proportional Directional Control Valve User Manual - cover page
Brand
Vickers
Document type
User Manual
Language
Chinese
Pages
39
File format
PDF
File size
3.1 MB
Published
19 September, 2011
Updated
20 October, 2026
MD5 checksum
D7F76507243D6E1B51E5623274657021

About this manual

The document provides detailed instructions for Vickers K(A)DG5V series two-stage proportional directional control valves without electrical feedback. These solenoid-controlled valves are designed for applications with repeated load conditions, such as mold closing/opening in injection molding machines. The manual covers various specifications including flow rates, pressure ratings, and coil data. This manual is written in Chinese.

What's inside

  • Introduction
  • Functional Symbols
  • Model Coding
  • Spool Data
  • Operating Data
  • Performance Characteristics
  • Installation Dimensions
  • Electrical Data
  • Application Data

Specifications

Max Operating Pressure (Spec 5)315 bar (4500 psi)
Max Operating Pressure (Specs 7,8,10)350 bar (5000 psi)
Max Flow Rate (Spec 10, Symmetrical)550 L/min (145 USgpm)
Max Flow Rate (Spec 7, Asymmetrical P-A)180 L/min (48 USgpm)
Electrical Plug StandardISO 4400 (DIN 43650)

Frequently asked questions

What is the recommended pilot pressure for full flow performance?

The minimum pilot pressure required is at least 45 bar (650 psi).

Is external or internal pilot bleed recommended?

External pilot bleed is the recommended configuration to prevent spool movement from pressure shocks.