Vickers DG3V-8 and DG5V-8 Directional Control Valve Manual

This document describes the features and characteristics of Vickers® directional control valves, including flow control, pilot pressure relief valve, hydraulic damping, and main stage stroke adjustment. The valve is suitable for applications with high flow rates and high pressures, and it has advantages such as mini-system capability, reliable operation, and high reliability.


Brand
Vickers
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
32
File format
PDF
File size
2.9 MB
Updated
29 September, 2023
MD5 checksum
6E6787C69D77AB5EEB5545B1F61F4B26

About this manual

This manual covers the DG3V-8 and DG5V-8 remote hydraulic directional control valves, describing their model coding, performance characteristics, valve‑core configurations, pressure‑drop curves and response times. Detailed installation dimensions, optional components, electrical data and mounting surface requirements are included.

Additional sections provide application data, oil cleanliness recommendations, special seal options, and part‑number references for ordering and service. The document is intended for engineers and technicians who install, commission, or maintain these valves in industrial hydraulic systems.

What's inside

  • Model coding
  • Performance characteristics
  • Valve core types and centering
  • Pressure‑drop curves
  • Response time
  • Installation dimensions
  • Optional components
  • Electrical data
  • Mounting surface
  • Application data

Specifications

Maximum flow rate700 l/min (185 USgpm)
Maximum pressure rating350 bar (5000 psi)
Operating temperature range-18 °C to 66 °C (0 °F to 150 °F)
Viscosity range75 to 600 cSt (15 to 128 Ssu)

Frequently asked questions

What is the maximum flow rating of the DG3V-8 valve?

The DG3V-8 valve is rated for a maximum flow of 700 l/min (185 USgpm).

What pressure can the valve withstand?

Both the DG3V-8 and DG5V-8 valves are rated for a maximum pressure of 350 bar (5000 psi).

How is response time defined in the manual?

Response time is the interval from the pilot pressure rise/fall to the resulting change in inlet pressure.

Download PDF (2.9 MB)