VIAVI IFF-45TS MK XIIA/TACAN Bench Test Set specification sheet covering interfaces, modes, signal generator parameters, accuracy, and pulse formats.
The VIAVI IFF-45TS MK XIIA/TACAN Bench Test Set performs transponder, interrogator, DME/TACAN, and ADS-B testing. It supports modes 1, 2, 3/A, C, S, 4, and 5, including secure modes 4 and 5, and provides a PC Windows based GUI.
Supported interfaces are IEEE-488, RS232, and Ethernet (VXI-11). The unit is certified to UL, CE, and DoD AIMS MK XIIA Level 1 and Level 2, and runs on 100-240 VAC, 50-60 Hz.
| Signal generator frequency range | 955 to 1223 MHz, 10 KHz resolution |
|---|---|
| Direct port output amplitude | 0.0 dBm to -110.0 dBm into 50 Ω |
| Accuracy at 25°C (direct port) | ±0.5 dB from 0.0 to -80.0 dBm |
| Operating temperature range | -10° to 55° C |
| Input power | 100-240 VAC, 50-60 Hz, 3 Amp fuse |
| Dimensions without controller | 17.75” W x 4” H x 21” D |
| Weight | 24 lbs (10 kg) |
| Supported interfaces | IEEE-488, RS232 and Ethernet (VXI-11) |
It supports IEEE-488, RS232 and Ethernet (VXI-11), with a PC Windows based GUI provided.
The frequency range is 955 to 1223 MHz with 10 KHz resolution.
The temperature range is -10° to 55° C (14° to 131° F).
It is certified to UL, CE, and DoD AIMS MK XIIA Level 1 and Level 2.