Installation and operating instructions for the Triton T90sr electric shower, covering safety, plumbing, electrical requirements, and commissioning.
This manual provides comprehensive installation and operating instructions for the Triton T90sr electric shower. It emphasizes that the unit is designed exclusively for gravity-fed cold water systems and must not be connected directly to a mains supply. The document outlines critical safety warnings, including prohibitions on using frozen units or restricting water flow, which could cause injury or void the warranty.
| Nominal Power | 9.0kW at 230V |
|---|---|
| MCB Rating | 40A |
| Minimum Cold Water Capacity | 114 litres (25 gallons) |
| Maximum Head Height | 10m |
| Minimum Flow Rate | 8l per minute |
| Maximum Inlet Temperature | 28°C |
| Minimum Inlet Temperature | 2°C |
No, under no circumstances should the T90sr electric shower be connected directly to a mains water supply.
The unit is designed specifically for gravity-fed cold water systems only.
Yes, a 30mA residual current device (RCD) must be installed in all UK electric and pumped shower circuits.