TRIOPTICS OptiCentric Optical Alignment and Centering Error Measurement System Product Overview

TRIOPTICS OptiCentric overview explains reflection and transmission centering-error measurement, lens errors, models, software and assembly options.


TRIOPTICS OptiCentric Optical Alignment and Centering Error Measurement System Product Overview - cover page
Brand
Trioptics
Category
Analyzer
Document type
Product Leaflet
Language
English
Pages
44
File format
PDF
File size
4 MB
Published
08 November, 2026
Updated
08 November, 2026
MD5 checksum
13ECB8E1431CB5B6E899C9CD0572454A

About this manual

The TRIOPTICS OptiCentric line covers inspection, alignment, cementing and assembly of optics. The document explains centering-error measurement in reflection and transmission modes, including the use of an autocollimator, CCD camera and reference axis, and lists measurable errors such as surface tilt, cementing error, air gaps and center thickness.

The overview lists OptiCentric models including METRO, SMART, MOT 100, MOT 300, MAX, MAX UP, 3D, 3D IR, Custom and PRO, with software, MOT extension modules, automated cementing and bonding, alignment turning and accessories. It also covers application overview, available configurations and order information.

What's inside

  • Principle of the Centering Error Measurement in Reflection and Transmission Mode
  • Comparison between Reflection and Transmission Mode
  • Centering Errors of Lenses
  • OptiCentric METRO
  • OptiCentric MOT 100
  • OptiCentric Software
  • Automated Cementing of Lenses
  • Automated Bonding of Lenses into a Mount
  • Alignment Turning
  • Accessories

Specifications

Measurement modesReflection and transmission
Measurable parametersTranslational displacement of a lens; tilt of a lens; surface tilt error; cementing error; tilt of the aspherical axis; air gaps and center thickness
Reference standardISO 10110-6
Tilt result unitarcsec
Run-out circle result unitµm

Frequently asked questions

What is a centering error?

According to the document, a centering error is present when the optical and the reference axis of a lens do not coincide, or differ in position or direction.

What is the difference between reflection and transmission measurement?

Reflection measurement provides information on the centering error of single surfaces; transmission measurement provides an overall error that combines the errors of all single surfaces.

What does the MultiLens procedure allow?

The MultiLens procedure measures the centering error of all single surfaces of a fully assembled objective without dismantling it.

In what unit can the lens-axis tilt result be given?

Transmission-mode lens-axis tilt results can be given in arcsec.