TPI 750a refrigerant leak detector instruction manual covering specifications, operation, battery and sensor replacement, and warranty.
The TPI 750a is a refrigerant leak detector capable of detecting all halogen-based gases. It offers selectable sensitivity and an adjustable tick rate to help service professionals pinpoint leaks in contaminated environments.
The manual provides operating instructions, battery replacement steps, sensor replacement steps, and warranty details. Standard accessories include the A712 sensor, instruction manual, and soft pouch A700.
| Power Supply | 2 "C" Alkaline Batteries |
|---|---|
| Sensor | Conductive Polymer Ionization (CPI) |
| Sensitivity | Selectable to 0.3 oz/yr 134a |
| Warm up | Approx 3 seconds |
| Response time | Instantaneous |
| Duty Cycle | Continuous |
| Battery Life | Approx. 30 hrs. |
| Size | 3.0" x 9.5" x 1.75" (77 x 240 x 47) mm |
| Weight | 1.1 lbs (500g) |
| Probe Length | 16" |
The warranty covers defects in materials and workmanship for one year after purchase, excluding the sensor, calibration, and batteries.
Replace the sensor when the red light stays on, the tick is erratic, or sensitivity is reduced.
Yes, an earphone can be plugged into the earphone jack for use in noisy environments.