Topcon NW500 Non-Mydriatic Retinal Camera User Manual

Instruction manual for the Topcon NW500 non-mydriatic retinal camera, covering components, specifications, operating principles, setup, and imaging procedures.


Topcon NW500 Non-Mydriatic Retinal Camera User Manual - cover page
Brand
Topcon
Category
Professional medical equipment
Document type
User Manual
Language
Japanese
Pages
3
File format
PDF
File size
506 KB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
1C307933D7B8BF4CCA9A85140A45718F

About this manual

This document is the Japanese instruction manual for the Topcon NW500 non-mydriatic retinal camera, a specially controlled medical device used to observe, photograph, or record the fundus through the pupil without contacting the eye. It lists the main unit and accessories, body-contact materials, electrical ratings, device classification, dimensions, operating environment, and the principles of observation, photography, recording, auto alignment, auto focus, auto shoot, and auto small pupil functions.

The manual then describes basic setup and use, including power and cable connections, chin-rest paper placement, patient information entry, patient positioning, control-panel adjustments, image capture, saving or deleting images, printing, and power-off. It also covers use with a PC and Ez Capture for NW500 software, use with a DICOM server, contraindications, and a note that auto focus, auto shoot, and auto small pupil functions cannot be used with the diopter correction lens. This manual is written in Japanese.

What's inside

  • Contraindications
  • Configuration
  • Electrical ratings
  • Device classification
  • Electromagnetic compatibility
  • Dimensions
  • Principles and functions
  • Operating environment
  • Intended use
  • Instructions for use

Specifications

Power supply voltageAC 100 V
Electromagnetic compatibilityIEC 60601-1-2:2014 compliant
Dimensions332–426 mm (W) × 540–680 mm (D) × 519–769 mm (H)
Operating temperature10°C to 35°C
Operating humidity30% to 90%, no condensation
Operating pressure800–1060 hPa

Frequently asked questions

What is the intended use of the NW500?

It is used to observe, photograph, or record the fundus through the pupil without contacting the eye and to provide fundus image information for diagnosis.

Can the auto focus, auto shoot, and auto small pupil functions be used with the diopter correction lens?

No. The manual states that these functions cannot be used when the diopter correction lens is used.

Which patients should not undergo imaging with this device?

Patients who have recently received photodynamic therapy (PDT); the prohibited period should be checked in the package insert of the administered photosensitive substance.

What is the power supply voltage of the NW500?

AC 100 V.