Thomson IOX/DCX Series IOT UHF Television Transmitter Technical Service Bulletin

Thomson IOX/DCX IOT UHF television transmitter service bulletin on periodic crowbar testing and thyratron replacement criteria.


Thomson IOX/DCX Series IOT UHF Television Transmitter Technical Service Bulletin - cover page
Brand
THOMSON
Category
Communications equipment
Document type
Service Manual
Language
English
Pages
4
File format
PDF
File size
76 KB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
1375B869EA8CC99C602D4C0E9D73234A

About this manual

This bulletin concerns Thomson IOX and DCX series IOT-equipped UHF television transmitters and stresses making crowbar testing part of regular monthly maintenance. The thyratron tube in the crowbar assembly has a finite life and may not fully suppress an internal IOT arc even when its protection circuits pass.

It describes three crowbar test procedures: off-line, on-line for transmitters with the type 410966-01 HPA controller, and true arc. In each test, the beam voltage must drop to near zero volts (< 5 kV); if beam voltage remains, the thyratron should be replaced immediately.

What's inside

  • Periodic Crowbar Testing
  • Procedure 990611a: Off-line Crowbar Test Fire Procedure
  • Procedure 990611b: On-line Crowbar Test Fire Procedure
  • Procedure 990611c: True Arc Crowbar Test Fire Procedure
  • Applicability
  • Prerequisites
  • Equipment Required
  • Comments

Frequently asked questions

Why should the crowbar be tested periodically?

The thyratron tube in the crowbar assembly has a finite life and may not fully suppress an internal IOT arc.

What beam voltage result indicates the crowbar test passed?

The beam voltage must drop to near zero volts (< 5 kV).

What is the default technician level password?

4444, if it has not been changed.

What is the default administration level password?

55555, if it has not been changed.