Thomson IOX/DCX IOT UHF television transmitter service bulletin on periodic crowbar testing and thyratron replacement criteria.
This bulletin concerns Thomson IOX and DCX series IOT-equipped UHF television transmitters and stresses making crowbar testing part of regular monthly maintenance. The thyratron tube in the crowbar assembly has a finite life and may not fully suppress an internal IOT arc even when its protection circuits pass.
It describes three crowbar test procedures: off-line, on-line for transmitters with the type 410966-01 HPA controller, and true arc. In each test, the beam voltage must drop to near zero volts (< 5 kV); if beam voltage remains, the thyratron should be replaced immediately.
The thyratron tube in the crowbar assembly has a finite life and may not fully suppress an internal IOT arc.
The beam voltage must drop to near zero volts (< 5 kV).