Installation and operation manual for Thomson Electrak 10 series DC linear actuators, covering models D12-05B5, D12-20B5, D24-05B5, and D24-20B5, including…
This manual provides complete information for installing and troubleshooting Thomson D12-05B5, D12-20B5, D24-05B5, and D24-20B5 DC linear actuators. It covers application notes, specifications, mounting procedures, electrical installation, wiring diagrams, and troubleshooting guidance.
The Electrak 10 actuators are load protected with a slip clutch, factory lubricated for life, and weather protected for outdoor use. The manual includes a wire gauge selection chart, switch requirements, connector specifications, and optional external limit switch wiring. A one-year warranty from Thomson covers defects in material or workmanship.
| Stroke Length | 4, 8 or 12 inches |
|---|---|
| Duty Cycle | 25% on time at 75°F at rated load |
| Life | 20,000 cycles, nominal |
| Motor Protection | Automatically reset thermal overload protection |
| Temperature Range | -15°F to +150°F |
| End Play | .070 inch maximum |
| Overload Protection | Mechanical load limit clutch |
| Static Loads | 3000 lbs. maximum |
The duty cycle is 25% on time at 75°F at rated load. For example, an actuator operating for 25 seconds must remain off for 75 seconds before operating again.
To extend the actuator, connect red to positive and yellow to negative. To retract, connect yellow to positive and red to negative.
DC actuators require double-pole, double-throw switches rated 20 Amp at 28 VDC with a center off position and two momentary contacts.
No, they are weather protected for outdoor applications but not waterproof and should not be used in underwater conditions.