Teledyne Isco 4501 Pump Station Monitor installation and operation guide covering setup, displays, data collection, maintenance, and specifications.
The Teledyne Isco 4501 Pump Station Monitor monitors single-speed pumps as a wet well cycles between full and empty and uses patented algorithms to calculate flow into and out of the pump station and each pump's pumping rate. Pump activity data is stored in battery-backed memory, and the monitor can be used for sewer flow monitoring, pump performance studies, and proactive pump maintenance.
The guide covers physical and electrical installation, digital and analog inputs and outputs, instrument displays and settings, data collection through RS-232 or an optional modem, and maintenance including fuse replacement, troubleshooting, and hardware settings. Specifications include a 12 VDC, 250 mA power requirement, storage for up to 29,000 events, and operating and storage temperature ranges.
| Size (H x W x D) | 3.75 x 3.75 x 7.1 in. (9.5 x 9.5 x 18.1 cm) |
|---|---|
| Weight | 1.4 lb. (0.63 kg) |
| Material | Polyphenylene Oxide |
| Power | 12 VDC, 250 mA |
| Display | Backlit liquid crystal, 2 lines x 16 characters |
| Keypad | Membrane, 4 position |
| Pump inputs | 3, rated 12 to 120V AC or DC |
| Digital inputs | 4, rated 12 to 120V AC or DC |
| Data storage memory capacity | 29,000 events maximum |
| Battery back-up life | 10-year internal battery life expectancy |
| Typical accuracy | ±1% totalized flow, ±8% cycle to cycle (monitor); ±1% totalized flow, ±5% cycle to cycle (Pumplink software) |
| Relay outputs | 2 normally open, rated 1 A at 30 V DC or 0.3 A at 125 VAC |
| Analog outputs | 2 proportional to inflow and outflow rates, 4 to 20 mA into a maximum of 400 ohms |
| Operating temperature | 0° to 140°F (-18° to 60°C) |
| Storage temperature | -40° to 140°F (-40° to 60°C) |
| Analog inputs (optional) | Optional eight analog inputs: 4-20 mA, 0-5 VDC, DIP switch-selectable |
The 4501 stores up to 29,000 events in battery-backed memory.
It requires 12 VDC at 250 mA.
Basic configurations allow data retrieval through a direct serial RS-232 connection.
The monitor is specified at ±1% totalized flow and ±8% cycle to cycle.