Installation and operation manual for TAKEX PB-IN-HF series active infrared beams, covering configuration, wiring, and mounting instructions.
This document provides the installation and operation guide for the TAKEX PB-IN-HF series of active infrared beams. The series includes models with external ranges up to 200m (PB-IN-50HF, PB-IN-100HF, PB-IN-200HF) and internal ranges up to 400m. Key features include four synchronized beams using AND logic to reduce false alarms from small animals, high-power infrared beams with selectable frequencies to avoid interference, and automatic sensitivity regulation (auto gain-lock). This manual is written in Polish.
| External Range (PB-IN-200HF) | 200m |
|---|---|
| Internal Range (PB-IN-HF Series) | Up to 400m |
| Recommended Installation Height | 70cm to 90cm (27.5" to 35.5") |
| Supply Voltage | 12V DC to 30V DC |
| Alarm Output Rating | 30V (AC/DC) 1A or less |
The sensor should generally be installed at a height of 70cm to 90cm (27.5" to 35.5").
The device features four synchronized beams connected in AND logic to help reduce false alarms.