Installation and maintenance guide for the Synventive PNC3008B02 hot runner actuator, with technical data, exploded view, tools, and service steps.
This document is section 8.2.2 of Synventive's Hot Runner System Installation Guide and covers the PNC3008B02 actuator. It provides technical data, an exploded view and parts list, required tools, and procedures for disassembly, assembly and valve pin adjustment.
The guide lists pneumatic operating data and forces, notes indirect cooling through the back plate, and describes lubrication and seal replacement steps. It also includes instructions for adjusting the valve pin to the basic position and for valve pin adjustment on a mounted hot runner system.
| Operation medium | Pneumatic |
|---|---|
| Pressure range | 6 - 12 bar (87 - 174 psi) |
| Maximum pressure | 14 bar (203 psi) |
| Flow rate | 2 l/min |
| Valve pin stroke | 8 mm |
| Adjustment | ± 1 mm via adjustment threads from topside |
| Closing force | 424 N / 6 bar (87 psi) |
| Opening force | 332 N / 6 bar (87 psi) |
| Cooling | Indirect cooling through back plate, max. 80 °C / 175 °F |
| Valve pin diameter | Ø 3 mm |
The pneumatic pressure range is 6 - 12 bar (87 - 174 psi), with a maximum pressure of 14 bar (203 psi).
The valve pin stroke is 8 mm.
Krytox GPL205 is specified for lubrication of the piston and ring seals.
Tools ATCYL13, ATCYL14, ATCYL15 and ATCYL16 are not included with the Hot Runner System and must be ordered from Synventive separately.