This document is section 8.2.2 of Synventive's Hot Runner System Installation Guide and covers the PNC3008B02 actuator. It provides technical data, an exploded view and parts list, required tools, and procedures for disassembly, assembly and valve pin adjustment.

The guide lists pneumatic operating data and forces, notes indirect cooling through the back plate, and describes lubrication and seal replacement steps. It also includes instructions for adjusting the valve pin to the basic position and for valve pin adjustment on a mounted hot runner system.

What's inside

  • Technical Data PNC3008B02
  • Exploded View PNC3008B02
  • Tools for Assembling, Disassembling and Adjusting the Actuator
  • Disassembling Actuator PNC3008B02
  • Lubrication of Piston and Ring Seals
  • Assembling the Actuator PNC3008B02
  • Adjusting the Valve Pin to the Basic Position
  • Valve Pin Adjustment at mounted Hot Runner System

Specifications

Operation mediumPneumatic
Pressure range6 - 12 bar (87 - 174 psi)
Maximum pressure14 bar (203 psi)
Flow rate2 l/min
Valve pin stroke8 mm
Adjustment± 1 mm via adjustment threads from topside
Closing force424 N / 6 bar (87 psi)
Opening force332 N / 6 bar (87 psi)
CoolingIndirect cooling through back plate, max. 80 °C / 175 °F
Valve pin diameterØ 3 mm

Frequently asked questions

What is the pressure range of the PNC3008B02 actuator?

The pneumatic pressure range is 6 - 12 bar (87 - 174 psi), with a maximum pressure of 14 bar (203 psi).

What is the valve pin stroke?

The valve pin stroke is 8 mm.

What lubricant is specified for the piston and ring seals?

Krytox GPL205 is specified for lubrication of the piston and ring seals.

Which tools must be ordered separately from Synventive?

Tools ATCYL13, ATCYL14, ATCYL15 and ATCYL16 are not included with the Hot Runner System and must be ordered from Synventive separately.