Sola-Hevi-Duty Silver Line SLD-12-6034-05T Linear Open Frame DC Power Supply Instruction Manual

Sola-Hevi-Duty SLD-12-6034-05T Silver Line linear open frame DC power supply instruction manual with specifications, connections, and output adjustment.


Sola-Hevi-Duty Silver Line SLD-12-6034-05T Linear Open Frame DC Power Supply Instruction Manual - cover page
Brand
Sola Hevi Duty
Category
AC-DC Power
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
262 KB
Published
22 November, 2026
Updated
22 November, 2026
MD5 checksum
E1778B4962D25D3D38752C4080E99D55

About this manual

This instruction manual covers the Sola-Hevi-Duty SLD-12-6034-05T Silver Line linear open frame DC power supply. It lists features, general specifications, voltage/current ratings, input and output specifications, fuse requirements, and AC input connections.

It describes remote sensing, optional OVP, overload protection, output adjustment steps, grounding notes, and mechanical dimensions. The PDF includes an English instruction page and a Spanish instruction page for the same model.

What's inside

  • Features
  • General Specifications
  • Voltage/Current Ratings
  • Input Specifications
  • Output Specifications
  • Input AC Connections
  • Mechanical Dimensions
  • Application Note
  • Output Adjustment

Specifications

Output ratings+5 V/6.0 A; +12 V/3.4 A
Output isolationOutputs are isolated from one another.
Operating temperature range0 to +50°C; derate to 40% at +70°C
Input voltage100/120/220/230/240 VAC selectable ±10%; 230 VAC +15%, -6%
Frequency range47-63 Hz
Transient response time50 µsec at 50% load change
Line regulation0.05% for ±10% change
Load regulation0.05% for 50% change
Ripple3.0 mV maximum peak-to-peak DC
Overload protection125 to 150% foldback current limit
CoolingForced air; 20 CFM required for full rating

Frequently asked questions

What are the output ratings of the Sola-Hevi-Duty SLD-12-6034-05T?

The outputs are +5 V/6.0 A and +12 V/3.4 A, and they are isolated from one another.

What input AC voltage is the unit shipped for?

The unit is shipped from the factory for 120 V input.

How is remote sensing enabled?

It is enabled by removing the shorting straps.

Should users adjust I. LIM?

No. I. LIM is factory set on all models and should not be adjusted by users.