Sola-Hevi-Duty SLD-12-6034-05T Silver Line linear open frame DC power supply instruction manual with specifications, connections, and output adjustment.
This instruction manual covers the Sola-Hevi-Duty SLD-12-6034-05T Silver Line linear open frame DC power supply. It lists features, general specifications, voltage/current ratings, input and output specifications, fuse requirements, and AC input connections.
It describes remote sensing, optional OVP, overload protection, output adjustment steps, grounding notes, and mechanical dimensions. The PDF includes an English instruction page and a Spanish instruction page for the same model.
| Output ratings | +5 V/6.0 A; +12 V/3.4 A |
|---|---|
| Output isolation | Outputs are isolated from one another. |
| Operating temperature range | 0 to +50°C; derate to 40% at +70°C |
| Input voltage | 100/120/220/230/240 VAC selectable ±10%; 230 VAC +15%, -6% |
| Frequency range | 47-63 Hz |
| Transient response time | 50 µsec at 50% load change |
| Line regulation | 0.05% for ±10% change |
| Load regulation | 0.05% for 50% change |
| Ripple | 3.0 mV maximum peak-to-peak DC |
| Overload protection | 125 to 150% foldback current limit |
| Cooling | Forced air; 20 CFM required for full rating |
The outputs are +5 V/6.0 A and +12 V/3.4 A, and they are isolated from one another.
The unit is shipped from the factory for 120 V input.
It is enabled by removing the shorting straps.
No. I. LIM is factory set on all models and should not be adjusted by users.