Sika Sika-101 Mortero Waterproofing Mortar Technical Sheet

Sika-101 Mortero is a cement-based waterproofing mortar for tanks, pools, retaining walls, and concrete surfaces. Easy to apply, breathable, and…


Sika Sika-101 Mortero Waterproofing Mortar Technical Sheet - cover page
Brand
SIKA
Document type
Product Leaflet
Language
Spanish
Pages
2
File format
PDF
File size
139 KB
Published
31 October, 2026
Updated
31 October, 2026
MD5 checksum
1FA336B68C2C62C74063E9DEAA1B0710

About this manual

Sika-101 Mortero is a cement-based waterproofing mortar designed for use on concrete surfaces such as tanks, pools, retaining walls, and foundations. It allows surfaces to breathe and is resistant to weathering. The product is easy to apply and maintain, with options for textured finishes. It can be used in contact with potable water and applied directly on non-porous surfaces without priming.

Application requires preparing the surface by cleaning and wetting it thoroughly. Mix 3 parts Sika-101 Mortero with 1 part clean water. Apply in two coats, with the second coat applied after 12 hours. Keep the surface moist during curing for best results. The product is available in 2kg, 5kg, 10kg, and 25kg bags and must be stored in dry, covered conditions. This manual is written in Spanish.

What's inside

  • Description
  • Uses
  • Advantages
  • Application Method
  • Preparation of Surface
  • Preparation of Product
  • Application
  • Technical Data
  • Precautions
  • Safety Measures

Specifications

Minimum Thickness1 mm in two coats
Mix Ratio3 parts Sika-101 Mortero to 1 part water
Density of Mixture2.3 kg/l approximately
ConsumptionApproximately 2 kg/m² for two coats
Minimum Temperature5°C
VOC Content< 340 gr/l

Frequently asked questions

Can Sika-101 Mortero be applied directly on non-porous surfaces?

Yes, it can be applied directly on non-porous surfaces without priming.

What is the recommended mix ratio for Sika-101 Mortero?

Mix 3 parts Sika-101 Mortero with 1 part clean water by volume.

How many coats should be applied?

Two coats should be applied, with the second coat applied after 12 hours.

What is the minimum temperature for application?

The minimum temperature for application is 5°C.

Download PDF (139 KB)