SIKA TU 7055 Measuring Transducer Operating Manual

Operating manual for the SIKA TU 7055 measuring transducer, covering installation, electrical connections, commissioning, and technical specifications.


SIKA TU 7055 Measuring Transducer Operating Manual - cover page
Brand
SIKA
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
673 KB
Published
21 October, 2026
Updated
21 October, 2026
MD5 checksum
E45341C1E496CB46CF2D395EA67060EB

About this manual

The SIKA TU 7055 is a measuring transducer designed to convert input signals from SIKA flow or volumetric sensors into standard current (0/4...20 mA) and voltage (0...10 V) output signals. It features a plastic casing for DIN EN 60715 rail mounting and includes integrated pull-up/pull-down resistors for specific sensor types.

What's inside

  • Device description
  • Safety instructions
  • Connections and function
  • Rail mounting
  • Electrical connection
  • Sensor connections (NPN/Inductive)
  • Output connections
  • Supply voltage connection
  • Commissioning
  • Maintenance and disposal

Specifications

Accuracy1% of the upper range value
Linearity0.15% of the upper range value
Temperature drift0.02% of the upper range value / K
Response time0.5 s
Supply voltage12...24 V DC
Current output range0/4...20 mA
Voltage output range0...10 V

Frequently asked questions

What is the intended use of the TU 7055?

It converts the frequency signals of SIKA flow or volumetric sensors into standard current and voltage signals.

Is the device maintenance-free?

Yes, it is maintenance-free and cannot be repaired by the user; defective units must be returned to the manufacturer.

Can the current and voltage outputs be used simultaneously?

Yes, both outputs can be used at the same time.