Technical bulletin with seawater cooling flow rates, pump power requirements, and pump options for all Seakeeper models.
This technical bulletin provides guidance for sizing and designing seawater cooling systems for Seakeeper products. It lists required flow rates, cooling water schematic drawing numbers, seawater pump power supplies, and pump power cycles for each Seakeeper model.
It also describes cooling system design notes, optional Seakeeper seawater pump assemblies, and alternative pump options that have been used successfully on existing installations. Final pump selection and system design remain the responsibility of the installer.
| Seakeeper 1 required seawater flow rate | 2-4 GPM / 7.6-15.1 LPM |
|---|---|
| Seakeeper 2 required seawater flow rate | 2-6 GPM / 7.6-22.7 LPM |
| Seakeeper 3 required seawater flow rate | 2-6 GPM / 7.6-22.7 LPM |
| Seakeeper 5/6 required seawater flow rate | 2.5-8 GPM / 9.46-30.3 LPM |
| Seakeeper 9 required seawater flow rate | 4-8 GPM / 15.1-30.3 LPM |
| Seakeeper 18 required seawater flow rate | 4-8 GPM / 15.1-30.3 LPM |
| Seakeeper 26 required seawater flow rate | 4-8 GPM / 15.1-30.3 LPM |
| Seakeeper 40 required seawater flow rate | 13-15 GPM / 49-57 LPM |
| Seakeeper 1 seawater pump power supply | 12 VDC, 15A max |
| Seakeeper 26 seawater pump power supply | 220 VAC, 5A max |
| Seakeeper 40 seawater pump power supply | 24 VDC, 20A max |
| Seakeeper 1 optional pump part number | 30331 |
| Seakeeper 18 optional pump manufacturer | Jabsco |
| Seakeeper 40 optional pump nominal flowrate | 21 GPM / 79 LPM |
The installer is responsible for final pump selection and system design.
One dedicated seawater pump should be installed per Seakeeper.
A flow-restrictor valve can be installed to regulate flow within Seakeeper specified limits.
Yes, seawater should travel in a continual upward direction from intake to outlet as much as practical.