Installation guide for the Seakeeper 4/4.5 gyro stabilizer covering service clearances, stringer grid lamination, and deck mount arrangements.
This is the Seakeeper 4 / 4.5 Generic Installation Guide (Product Seakeeper 4 / 4.5, Document # 90736 Rev 2). It is issued for information only, to illustrate typical gyro installations, and is marked "not for design" with no guarantee expressed or implied. The arrangements presented are based on the Seakeeper 4 / 4.5 resultant forces acting at each corner of the unit, with Seakeeper suggesting a safety factor of 3.0 (a safety margin of 2.0). All dimensions in the document are given in MM [IN].
The guide covers minimum service clearances, laminated FRP stringer bolt-in arrangements (molded and refitted), a typical lamination schedule and lamination comparison table, molded stringer grid arrangement and lamination, and a preliminary deck mount installation. General notes call for bonding with SCIGRIP SG300 or PLEXUS MA590 adhesive, describe the aluminum installation structure bolted to the gyro with M16 cap screws torqued to 135 ft-lbs, and specify deck lamination conditions and maximum spans.
| Vertical force at each corner (Fz) | 2989 lbs up and down (13.30 kN) |
|---|---|
| Longitudinal force at each corner (Fx) | 1785 lbs fore and aft (7.82 kN) |
| Lateral force at each corner (Fy) | 182 lbs port and starboard (0.81 kN) |
| Suggested safety factor | 3.0 (safety margin of 2.0) |
| Gyro-to-frame fasteners | M16x2.0x100mm hex head cap screw, Class 10.9, 8 places |
| Fastener torque | 135 ft-lbs |
| Foundation adhesive | SCIGRIP SG300 or PLEXUS MA590, min. tensile strength 2000 PSI |
Seakeeper suggests a safety factor of 3.0, which yields a safety margin of 2.0, and notes it may need to be increased depending on the vessel's operational profile.
No. It is for information only, to illustrate typical gyro installation, is marked not for design, and no guarantee is expressed or implied.
The foundation shall be bonded to the deck sole with SCIGRIP SG300 or PLEXUS MA590 adhesive with a minimum tensile strength of 2000 PSI.
It is bolted using M16x2.0x100mm L hex head cap screws, Class 10.9, in 8 places, torqued to 135 ft-lbs.