Instruction manual and command description for the SCS Tracker/DSP TNC firmware version 1.7, covering hardware features, DIP-switch configuration, and…
This manual describes the SCS Tracker/DSP TNC, a DSP-based terminal node controller for packet radio and APRS tracking. It covers hardware features, operating-system highlights, DIP-switch basic configuration, and software-based configuration.
The document also explains terminal mode and host mode operation, the TRConfig configuration program, and the available commands, including DIP-switch settings for tracking mode, BIOS updates, USB baud rate, and default or user configuration.
| CPU | 100 MIPS DSP |
|---|---|
| USB virtual baud rates | 38400 or 115200 Bd |
| Current drain | 15-90 mA at 13.8 V, typically 50 mA |
| Tracking-mode current drain | Less than 20 mA at 13.8 V |
| Virtual channels | 11 (one monitor channel and 10 connect channels) |
| Parallel packet-radio connects | 10 |
| Housing | Metal housing |
| Oscillator | TCXO |
It selects normal TNC mode when OFF and energy-saving tracking mode when ON.
The virtual COM port uses 38400 Bd when DIP-switch 2 is OFF and 115200 Bd when it is ON.
It provides 11 virtual channels: one monitor channel and 10 channels for packet-radio connects.
The current drain is 15-90 mA at 13.8 V, typically 50 mA.