Certified configuration guidelines for Ruckus Wireless ZoneDirector controllers and ZoneFlex access points when used with Spectralink Wireless Telephones.
This document provides certified configuration guidelines for Ruckus Wireless ZoneDirector 1100, 3000, and 5000 controllers and ZoneFlex 7363 and 7982 access points when used with Spectralink Wireless Telephones. It details the setup, software upgrades, and system settings required to ensure interoperability and high performance between the wireless infrastructure and Spectralink handsets.
| Certified Controllers | ZD1100, ZD3000, ZD5000 |
|---|---|
| Certified Access Points | ZF 7363, ZF 7982 |
| AP Radio Frequencies | 2.4 GHz (802.11b/g/n), 5 GHz (802.11a/n) |
| Supported Security Protocols | None, WEP, WPA-PSK, WPA2-PSK, WPA2-Enterprise |
| Default IP Address | 192.168.0.2 |
| Default Admin Credentials | admin / admin |
| Minimum Call Capacity per AP | 8 calls |
The default IP address of the Zone Director is 192.168.0.2.
The default Admin name is admin and the default Password is admin.
The certified handsets include Spectralink 8020/8030 and 8440/8441 and 8450/8452/8453.
The recommended network topology is Switched Ethernet.